Clover Incinerator

Nanjing Clover Medical Technology Co.,Ltd.        

¡¡ ¡¡
¡¡ Call us on  0086-25-8461 0201  [email protected] ¡¡

 

¡¡ ¡¡ ¡¡ ¡¡




¡¡



¡¡

¡¡

 Nanjing Clover Medical Technology Co.,Ltd.
 Tel: +86-25-8461 0201
 Fax: +86-25-8461 0406

 Website: www.cloveridea.com.cn
 Email:
cloverincinerator@Gmail.com

About Us

Small Incinerator

Incinerator YD10C

Incinerator YD20C

Incinerator YD30C

Incinerator YD50C

Medical Incinerator

Incinerator YD30

Incinerator YD50

Incinerator YD100

Incinerator YD150

Incinerator YD300

Incinerator YD500

Incinerator YZ20

Incinerator YZ50

Incinerator YZ100

Incinerator YZ150

Animal Cremation

Incinerator Burn Rate

10kgs per hour

20kgs per hour

30kgs per hour

50kgs per hour

100kgs per hour

150kgs per hour

300kgs per hour

500kgs per hour

Incinerator Burner

Light Oil Burner

Gas Burner

YZ Incinerator

Certificate

How to Buy Incinerator

Market Analytics

Contact Us

¡¡

¡¡

¡¡

¡¡

CLOVER Incinerator

Call us on  0086-25-8461 0201  [email protected]

China Medical Incinerators /  Animal Cremation / Waste Incinerators

¡¡

¡¡

Model YD-100 
 Burning Rate  100 kgs/hour
Feed Capacity 200 kgs
Paimary Combustion Chamber 1200 Liters
Secondary Combustion Chamber 500 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 0.9Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 14--28 kg/hour
Gas Consumption (Natural Gas) 10--32.2 m3/hour
Internal Dimensions 130 x 100 x 90cm (paimary chamber)
External Dimensions 220 x 180 x 360cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 55 x 80cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 4300 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800¡æ--1000¡æ
Secondary Chamber Temperature 1000¡æ-1200¡æ
Residency Time 2.0 Sec.
Burning Efficiency £¾98%
Waste Lower Calorific Power 3000Kcal

MEDICAL WASTE INCINERATOR SPECIFICATIONS Capacity (4000 kg/day). The unit should have the following features:
* Automatic feeding
* Automatic ash / leftovers removal
* Flue gas filtration system.
* The technical & financial offer should include installation & testing and staff training.

***The offer should be itemized. IMPORTANT INFORMATION:
1 Emission standards : ( EU ) ¡ª
2 Waste type: Hazardous Medical Waste
3 Approximate moisture content: max. 30%
4 Glass content: max. 15%
5 Building Roof Height: 8 meters
6 Height of chimney above roof (required): at least 3 meters
7 Fuel to be used : No. 2 ( diesel ) ( Fuel specifications attached )
8 Power: 380 V, 3 phase

9 Space available inside the existing building: (Bidders should visit the building to choose the best location for installation coordinating with university engineers)
10 Waste filled in (max. 70X120 cm ) polyethylene bags ¨C

I would like to list the following points that are mentioned in the special conditions ( in Arabic), and are not mentioned in the technical specs:

1- The price of each of the following components should be listed separately, as the university might not order it,:
¨C Flue gas cleaning system. If you can send us two alternatives, dry scrubber and wet scrubber type, it would be great.
¨C Automatic feeder
¨C Automatic ash removal
¨C Continuous emissions monitoring and recording system

2- The delivery period is very important. The whole tender period is 120 days, including supply, transportation and installation of the unit???!!!

3- The offer should include separately a priced list of reco

¡¡ ¡¡