On-Site Incinerator Solutions for Health Centers in Kenya and Uganda Effective medical waste management remains a […]
How much fuel does an incinerator use? Most fuel-assisted incinerators with a capacity to destroy 100 to 150 kilograms of waste per day consume 5 to 8 liters per hour of fuel (4 to 6.5 kilograms of gas)   What are three disadvantages of incinerators? Disadvantages of Waste Incineration     It is Expensive. The installation of an incineration plant is an expensive process. …     Pollutes the Environment. …     Damaging Public Health. …     The Possibility of Long-term Problems. …     Ash Waste Can Potentially Harm People and the Environment. …     Environmental Racism. smart ash incinerator incinerator diesel incinerator south africa package medical waste incinerator   […]
Model YD-100 Picture Burning Rate 100-150 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chamber 500 […]
HICLOVER – Medical Environmental  Model YD-30 (Custom Edition) Picture   Burning Rate  average 30 kgs/hour Feed Capacity average […]
Modern Medical Waste Incinerators Strengthen Health and Environmental Safety in Africa [City] C [Date] C With […]
Combustion Chamber:  · Horizontal cylindrical design  · Inner surface carried out with first-rate refractory material, high temperature proof,  · Combustion chamber volume; 5,3 approximately.  · 1 No. loading door set on the frontal edge of the burning chamber, having a whole section  crossing, suitable to load the Hospital waste material and to unload the ashes.  · Burner capacity (under full power) 30-40 Kg/ Hour approximately  · Operating Temperature: 700-900 cXC or better  · Standard Color: Black  HICLOVER YD30(PLC) 30-50 kg/hour 60kg/feeding PLC Automatic 360L(0.36M3) 100x60x60cm 200L […]
Bridging the “Blank Spots” in Medical Waste Management at Small Hospitals and Township Clinics Across many […]
Burkina Faso Biological Waste Management Burkina Faso, a landlocked country in West Africa, faces significant challenges […]
Mobile and Containerized Incinerator Solutions for Kenya’s Referral Hospitals and Emergency Camps Kenya’s healthcare system and […]
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com Double Combustion Chamber,Double […]
how does the incinerator works? the incinerator mainly for medical waste and animal waste treatment with oil/gas fired in the […]
Role of Medical Waste Incinerators in Modern Public Health Systems In modern healthcare, the safe disposal […]
Hidden Biological Risks in Medical Waste: Why Proper Incineration Matters More Than Ever Medical waste has […]
Epidemic Intelligence and Medical Waste Incineration: Building a Safer Future Introduction Global health security depends on […]
  Items/Model TS1000 Picture   Principle Solid Waste Incineration Treatment Burn Rate Average 1000kg/hour Feed Capacity Average […]
The Post-Pandemic Surge in Medical Waste: Can Incineration Capacity Keep Up? A Growing Global Concern Since […]
Air Pollution Control Systems for Incinerators in Tanzania: HICLOVER Dual Chamber Solutions The growing demand for […]
Mobile Small Scale Medical Waste Incinerator with Trolley(E-Power) or Wheel Model YD-30  Picture   Burning Rate  […]
Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes Hight […]
Rwanda Waste Management Incinerator Solutions with HICLOVER Rwanda has made significant progress in improving environmental infrastructure, […]
Advanced Medical Waste Incineration Solutions for Mauritania’s Healthcare Sector Addressing the Growing Waste Management Challenge Mauritania’s […]
CONTAINERISED WASTE INCINERATOR Incinerator Items/Model HICLOVER TS150(PLC) Picture   Burn Rate (Average) 100-150 kg/hour Feed Capacity(Average) […]
Waste Incineration Treatment Diesel Oil type Model TS150 Main Parts List as below: Primary combustion chamber […]
Industrial Waste Incinerator Solutions for Kenya’s Energy and Mining Camps Introduction: Waste Challenges in Industrial Camps […]
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50(PLC) Picture   Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity […]
Waste Incinerator (Containerized Mobile Incinerator) Capacity: Average 50 kgs per hour Model CA50 Internal Dimensions 100 […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping […]
Mobile and Containerized Bio-Medical Incinerators in Kenya: HICLOVER’s NEMA-Compliant Solutions for Aid Projects Growing Need for […]
Model YD-30M Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator  Control […]
Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture   Principle Medical Waste Incineration Treatment Burn […]
Incinerator for Animal Crematory Pig Farm Model A1200 *** 3 sets Burners *** Good for animals […]
HS Code for waste incinerator 84178050 Item Specification Model TS100 PLC Main Product List per 01 […]
Incinerator Items/Model HICLOVER YD30(PLC)     Burn Rate (Average) 15kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC […]
news from: http://www.chinadaily.com.cn/a/202002/01/WS5e347a86a310128217273ead.html  WHO declares outbreak constitutes international public health emergency China vowed on Friday to work […]
United Nations and WHO Initiatives in Medical Waste Incineration: Global Standards and HICLOVER Solutions Medical waste […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic […]
Incinerators must  be able to support different power sources (PV solar system ,  diesel Electric generator […]
Pets Bone Crusher Processing Center Machine
Medical Waste Classification & Pre-Treatment Comparison (Europe vs China vs Africa) Item Europe (EU developed countries) […]
biohazard waste disposal guidelines 1. The ground should be flat when install the incinerator. There should be 100cm at least between the incinerator  and the walls on the two sides and the back, which is in convenient maintenance and repair. 2.  A), Place the incinerator main body(combustion chamber) and fixed with bolts and Asbestos tape. B), Place the wet scrubber system and fixed with bolts and Asbestos tape. C). Install chimneys and fixed with bolts, Asbestos tape and Steel Rope. D). Fix the incineration house roof. E). Fix burner, blower, wind tube, electric system, fuel system. 3. Check the electric wire: the incinerator’s electric circuit should be linked with the ground wire to guard against current leakage.  The link-up of the electric wire should be checked carefully before starting the incinerator, in case of wrong link-up or leakage. 4. Check of the fuel supply system: Except the Burner’s soft pipe which is used for the fuel flowing-in and flowing-back, all the rest pipes must use brass or steel pipe. No leakage is allowed at pipe junctions. Any leakage should be blocked in time. 5. Install steel rope with the chimney, to avoid tilt by wind.  6. Install net cover at the blower, to avoid sundries. 7. If the fuel is Natural Gas with gas burner, please contact with local administration section and install gas supplier system. 8. Crane or forklift is necessary when download/upload/install incinerator.  9. Topped work house roof after installation. […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture   Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding […]
Double Combustion Chamber Containerized Mobile Incinerator. Double Combustion Chamber, The incinerator design with primary combustion chamber, […]
HICLOVER Top Feeding Door Waste Incinerators ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional […]
平面口罩机参数: Semi-Automatic Mask Machine l Power supply: 3.3KW mono phase l Mask Size: 175mm*80-100mm (two or three layers) l Nonwoven […]
Animal Crematory Incinerator Capacity: Average 80kgs per feeding Item Specification Model A900 Internal Dimensions 120 x […]
The equipment proposed shall be an incinerator specialised for Medical Wastes.  Medical waste may consist of […]
100 Kg/Hr Bio-Medical Waste Incinerator, wet scrubber/spary tower optional. 2 combustion chambers, italy burner, APO function,    PLC auto control […]
Kenya Expands Access to Mobile Medical Waste Incineration for Hospitals and Aid Projects Nairobi, Kenya C […]
Q: what is kind of waste can use in this equipment? A: This equipment for medical […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Equipment Technical Specifications Model TS30S Picture   Feed Capacity 78 Liters for […]