Category: Medical Environmental

Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture   Principle Medical  Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) *** […]
Waste Disposal Methods in Hospital • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall […]
having waste from production process which is having very fine/powder material with moisture of 40%. Will this machine suitable for this application. For power waste, proposal plus wet scrubber system. Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust.   Optional 3 section type: Wet Cooling Spray Scrubber+Wet Dust Scrubber+Fog and Water Separator. […]
SIEMENS Control Unit for OIl Burner  LOA24.171B27  Spare Parts for Incinerator Burner What can be burned in an incinerator? A material commonly associated with waste incineration is municipal solid waste (MSW).  This type of waste is typically general waste such as household waste, food waste,  cardboard, and paper. All of these are safe to incinerate. […]
Items/Model TS1000 Picture   Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil […]
Items/Model HICLOVER TS150(PLC) (Mobile Type) N1155 Picture  mobile incinerator Principle Waste Incineration Treatment,trash incinerator Burn Rate Average 150 kg/hour Feed Capacity Average 150kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) […]
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration  Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor […]
BURNING RATE : -100-150kgs per hour MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY : COMPULSORY DENSITY INSULATION : 50 mm high Refractory capacity : min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME : […]
Waste Incinerator (Containerized Mobile Incinerator) Capacity: Average 50 kgs per hour Model CA50 Internal Dimensions 100 x 80 x 70 cm Main Product List Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 units Oil Tank (if oil fuel): 200Liters ISO […]
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion,Medical waste management pdf. The […]
Items/Model TS250(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 210x88x110cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Average 24.2(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display […]
Incinerator for Medium type Hospital 100 -200 Kg per day incineration at south of switzerland fabrication incinerateur waste to energy technologies elastec incinerator hospital waste management Incinerator Items/Model TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed […]
  pictures of 500kg per hour machine   Items/Model TS500(PLC) Picture   Principle Medical Waste Incineration Treatment how many burners does the primary have Burn Rate Average 500 kg/hour,if 500kg has 1 burner Feed Capacity Average 500kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L Internal Dimensions 190x120x120cm Secondary Chamber 1300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power […]
Item Specification Model YD-30C (customer made model) Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy gas burner: 02 units Oil Tank (if oil fuel): 100Liters Model YD-30C Feed […]
you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including […]
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 […]
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour *(50/100/200kgs/hour […]
we use latest incinerator technology with high temperature combustion with 2 or 3 chambers, with wet scrubber or dry scrubber system and auto control system incinerator.   medical waste incinerator spare parts in stock for our customer, including air fan, burners, control case, temperature element.  the small scale equipment for laboratory incinerator specification like 10kgs per hour is hot sale in market, we supply cheap cost. […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Incinerator Model TS10 PLC, Overview   This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Items/Model TS10(PLC)       Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage […]
Advantages of Waste Incineration     Decreases Quantity of Waste. …     Efficient Waste Management. …     Production of Heat and Power. …     Reduction of Pollution. …     Incinerators Have Filters For Trapping Pollutants. …     Saves on Transportation of Waste. …     Provides Better Control Over Odor […]
Model WS-35 Picture Burning Rate Average 35 kgs/hour Feed Capacity Average 80 kgs Primary Combustion Chamber 460 Liters Secondary Combustion Chamber 200 Liters Third Combustion Chamber 200 Liters Smoke Filter Chamber Wet Scrubber System Feed Mode Manual Voltage 220V Power 2Kw Fuel Type Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) *** Gas Consumption […]
Waste Incineration Treatment Diesel Oil type Model TS150 Main Parts List as below: Primary combustion chamber Secondary combustion chamber smoke filter chamber incinerator PLC control case chimney, 10meters, stainless steel Italy Oil fule burner oil tank 300liters with full spare parts: oil burner, air blower, temperature thermocouple
Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get high temperature. Incinerator request 1/2/3/more […]
Items/Model TS75 Picture   Principle Solid Waste Incineration  Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 600L Internal Dimensions 100x60x100cm Secondary Chamber 300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (L/Hour) 15-20 Natural Gas Consumption (m3n/hour) ** Temperature Monitor Digital Display Temperature […]
Average 50-100 kg/hour Burn Rate   Items/Model TS75(PLC) Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Face Oil Paint 800℃ Combustion Chamber 768 Liters (0.768M3) Internal Dimensions 1200x800x800mm Secondary Chamber 384 Liters (0.384M3) Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/240V 50Hz 1P […]
Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.5Kw Oil Consumption (kg/hour) Average 28(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank […]
Hiclover supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour.  The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from  Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour  and 50kgs per hour. We are famous small scale incinerator manufacturer […]
Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture   Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) Average 24.2(D.O) Gas Consumption (m3n/hour) Average 21.3(LPG) Temperature […]
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic)  01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
Smallest Waste Incinerator for PPE waste face mask glove waste Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney ave 10kgs per hour, 100kgs per day(10hr/day working) Equipment Technical Specifications Model YD-10 Picture   Feed Capacity Average 20 kgs per feeding Burning Rate Average 10 kgs per hour Burning Time […]
Design for Pets Cremation Business Movable platform & Auto. Door Independent Position for Small Pet Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business Model A1500 Picture Burning Rate Average 150 kgs/hour Feed Capacity Average 350 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes […]
Items/Model TS500(PLC) Picture   Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700Liters (2.7m3) Internal Dimensions 190x120x120cm Secondary Chamber 1300Liters (1.3m3) Smoke Filter Chamber Dry Scrubber Chamber Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (kg/hour) Average 44(DO) Gas Consumption (m3n/hour) Average 53(NG) Temperature Monitor Digital […]
Model A1500(Movable platform & Auto. Door) Picture   Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 34 kg/hour […]
Mobile Containerized Waste Incinerators pets or human cremation emergency use   Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x […]
50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Model YD-50  Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs Primary Combustion Chamber 900 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. […]
High Temperature Protection Gloves and  High Temperature Protection Masks for incinerator operation Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   how to incinerate aerosol spray incinerator for sanitary napkins for schools dial thermometer for incinerators mobile incinerator medical waste what are the costs and benefits of building a brick incinerator for hospital drum inceniration Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) […]
hazardous waste disposal incinerator http://www.military-camps-incinerator.com/  Incinerator Items/Model HICLOVER TS100(PLC) HICLOVER TS150(PLC) Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour Feed Capacity(Average) 200kg/feeding 300kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) 1500Liters(1.5m3) Internal Dimensions 120x100x100cm 1500x1000x1000mm Secondary Chamber 600L 750Liters(1.0m3) Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V Power 0.7Kw […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator 100kg per hr 5. INDOOR INCINERATOR HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration […]
Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Incinerator Smoke StandardA: China Government Standard: No.GB18484-2001. Q: Treatment capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time per day up to 24 hours. Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We supply all documents and incinerators easy to installation and operation. Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi degree. Q: Incinerator Control ModeA: Default Control mode is common control case. PLC mode according to model and order. Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd per year maintenance according model, use situation.  One person can service 02 unit incinerators. The staff should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour […]
Incinerator for Animal Crematory Pig Farm Model A1200 *** 3 sets Burners *** Good for animals or big pets *** Double Combustion chamber *** stainless steel chimney *** Italy made oil burners *** 1200Liters(1.2m3) big chamber Model A1200 Picture Burning Rate Average 50 kgs/hour Feed Capacity Average 100 kgs/feeding Primary Combustion Chamber 1200 Liters Secondary […]
Diesel Biogas Dual Chamber Incinerator, with diesel oil and Biogas burner    Incinerator Items/Model HICLOVER TS50   Burn Rate (Average) 50 kg/hour Feed Capacity(Average) 100kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Dual chamber up to 50 kg per hour semi-automatic Independent control of primary and secondary temperatures via control panel 850 -1100 C 1000- 1200 C >= 2 seconds <5% Electronic control panel providing friendly interface for operators with minimal training Mobile: +86-138139 31455(WhatsApp) Website: www.hiclover.com  Email:     [email protected]        Email:    […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Model YD-30  Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 kg/hour Gas Consumption (Natural Gas) […]
Is medical waste an incinerator? What is Medical Waste Incineration? Medical waste incineration is the process of burning specific wastes, including pathological, trace chemotherapy and non-hazardous pharmaceutical wastes as it is considered the safest, most effective means of treatment and prevents harm to the environment and our health in general.   How medical waste is incinerated? The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases. What is incinerators used in hospitals? Medical incinerators are designed safely to dispose of harmful materials at high temperatures. The process ensures no harmful gases are released  into the environment. Medical waste incinerators have scrubbers to clean the polluted gases and other particulate matter.   Can biomedical waste be incinerated? As stated by Health Care Without Harm, non-incineration treatment technologies are a growing and developing field. Most medical waste is incinerated, a practice that is short-lived because of environmental considerations. The burning of solid and regulated medical waste generated by health care creates many problems.   What are the types of incinerator? The following are types of incinerators:     ROTARY KILN.     FLUIDIZED BED.     LIQUID INJECTION.     MULTIPLE HEARTH.     CATALYTIC COMBUSTION.     WASTE-GAS FLARE.     DIRECT-FLAME.   Which biomedical waste is incinerated? The 4 categories that medical waste falls under are General, Infectious, Hazardous and Radioactive. Biomedical waste is incinerated in either a hospital  incinerator or through industry standard biomedical waste incinerators.       Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ). 2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk. 3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization […]
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce. ※Main Feature:— Double Combustion Chamber— Double Italy Burner–Burning Rate: 10-100kgs per hour–Combustion Chamber: 0.1M3-1.2M3— Mobile Incinerator, Standard shipping containers, Easy to move/transport system— Free Installation, Pre-installed incinerator, Ideal for camps— Ultraviolet lamp sterilization inside Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L […]
Curing Duration,need a small incinerator, they discard 100 liters of covid masks daily.batch load, direct fire,  mobile incinerator for a variety of applications including medical waste. The unit is one of the lightest in its class ,  facilitating deployment for virus outbreaks and disaster relief operations. Primarily running on diesel 1. Where can I watch a video of a real-life application? 2. The modulating under air burners ensure consistent high temperatures needed to destroy infectious waste,  whilst retaining the flue gas for sterilization. Simply load waste into the chamber, close the door and turn on the unit. 3. When approved and paid for, how many days for shipment? 4. As per the requirement we have ordered an Incinerator that can process 100kg hospital waste and as per the  end user they are only able to put 3 bags of waste which are approximately 10kg each. So we are only able to  process 30 Kg of waste instead of 100Kg. As per the hospital the chamber volume is very small and can not process 100kg hospital waste 5. Can you give me the listing of extras needed, and  installation of the TS150 PLC Incinerator and am in  need of technical assistance? 6. What are the most commonly needed repair parts?a)   Waste Auto Loading Ram Hopper  b)   Standard Tools (What the tools are there?, Please figure out) c)   Recommended spare parts (1 year) (such as burner, refactor cement, temperature probe, etc.) d)   Commissioning and Training  e)   Support wires, clamp and bracket as chimney is 33 m height              HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)   Waste Incinerator RFQ(Request for Quotation) http://www.hiclover.com/ad/rfq/   EStore for Waste Incinerators http://www.haiwos.com   2022-06-24 […]