HICLOVER TS100 Top-Loading Incinerator C High-Efficiency Waste Disposal Solution

Share this post on:

HICLOVER TS100 Top-Loading Incinerator C High-Efficiency Waste Disposal Solution


The HICLOVER TS100 top-loading incinerator is a robust and efficient waste treatment system engineered for hospitals, laboratories, industrial facilities, and community waste centers. Designed with advanced combustion technology, it provides a clean, safe, and environmentally friendly method of disposing of medical, general, and animal waste.

1. Overview of the HICLOVER TS100 Incinerator

The TS100 model features a top-loading design that simplifies waste charging and maximizes chamber capacity. Its heavy-duty structure, refractory-lined chambers, and PLC-based combustion control make it one of the most durable and reliable incinerators in its class.

Key features:

  • Top-loading system: Allows easy loading of waste materials directly from above, reducing handling risks and improving operator safety.

  • Dual-chamber combustion: Ensures complete waste destruction with high temperature in the primary chamber (850C1100°C) and clean gas re-burning in the secondary chamber (>1100°C).

  • Automatic control: Optional PLC control panel with temperature sensors and timers ensures stable operation and minimal operator intervention.

  • Fuel flexibility: Compatible with diesel, natural gas, or LPG burners for global deployment versatility.

  • Compact, reinforced structure: The incinerator body is built with high-strength steel and refractory lining for long service life and high thermal efficiency.

2. Technical Performance

Parameter Specification
Model TS100
Feed Capacity 100C120 kg/hour
Chamber Volume Primary: 1.2 m3 / Secondary: 0.6 m3
Loading Mode Top-loading
Combustion Temperature 850C1100°C
Fuel Type Diesel / LPG / Natural Gas
Control System Manual or PLC automatic
Construction Refractory-lined steel chamber
Optional System Wet scrubber or dry filtration system

The TS100 incinerator achieves 99.9% combustion efficiency, ensuring minimal ash residue and compliance with international emission standards such as EU IED, WHO, and GB18484-2020.

3. Advantages of the Top-Loading Design

The top-loading chamber offers key operational benefits:

  • Simplified waste handling―operators can load waste directly using bins or lifting devices.

  • Improved safety―no side-door exposure during operation.

  • Optimized internal airflow―vertical layout ensures consistent flame distribution and complete combustion.

  • Compact footprint―ideal for containerized or trailer-mounted installation.

4. Applications

The TS100 model is widely adopted by medical institutions, relief organizations, military camps, and industrial complexes for safe on-site waste disposal. Typical uses include:

  • Medical waste treatment (infectious materials, sharps, PPE, etc.)

  • Animal carcass disposal in veterinary clinics and farms

  • Municipal waste management in remote or high-density areas

  • Industrial solid waste reduction

5. Environmental and Safety Compliance

The TS100 system integrates optional wet scrubber, quench tower, or baghouse filter modules for effective flue gas purification. These systems remove particulates, acid gases, and odors, ensuring that emissions meet international air quality standards.

In addition, the double-chamber and high-temperature design guarantees that dioxins and harmful gases are fully decomposed before exhaust discharge.

6. Global Projects and Deployment

HICLOVER incinerators are deployed in over 40 countries, including Kenya, Afghanistan, Tanzania, Oman, and Papua New Guinea, and are widely recognized by organizations such as the UNDP, WHO, and World Bank. The TS100 model, in particular, is often selected for healthcare and emergency waste treatment projects due to its durability and simple operation.

7. Why Choose HICLOVER

  • Over 20 years of manufacturing expertise

  • Proven reliability in extreme environments

  • Flexible design options (stationary, skid-mounted, or containerized)

  • Global after-sales support and spare parts availability

8. Contact Information

For technical details, quotations, and customization requests, contact:
HICLOVER C Waste Incinerator Manufacturer
Website: www.hiclover.com
Email: [email protected]

Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2025-11-17/10:31:53

Incinerator Items/Model

HICLOVER TS100(PLC)

 

Burn Rate (Average)

100kg/hour

Feed Capacity(Average)

150kg/feeding

Control Mode

PLC Automatic

Intelligent Sensor

Continuously Feeding with Worker Protection

High Temperature Retention(HTR)

Yes (Adjustable)

Intelligent Save Fuel Function

Yes

Primary Combustion Chamber

1200Liters(1.2m3)

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Burner Type

Italy Brand

Temperature Monitor

Yes

Temperature Thermometer

Corundum Probe Tube, 1400℃Rate.

Temperature Protection

Yes

Automatic Cooling

Yes

Automatic False Alarm

Yes

Automatic Protection Operator(APO)

Yes

Time Setting

Yes

Progress Display Bar

3.7 in” LCD Screen

Oil Tank

200L

Chimney Type

 Stainless Steel 304

1st. Chamber Temperature

800℃–1000℃

2nd. Chamber Temperature

1000℃-1300℃

Residency Time

2.0 Sec.

Gross Weight

7000kg

External Dimensions

270x170x190cm(Incinerator Main Body)

Burner operation

Automatic On/Off

Dry Scrubber

Optional

Wet Scrubber

Optional

Top Loading Door

Optional

Asbestos Mercury Material

None

Heat Heart Technology(HHT)

Optional

Dual Fuel Type(Oil&Gas)

Optional

Dual Control Mode(Manual/Automatic)

Optional

Temperature Record

Optional

Enhanced Temperature Thermometer

Optional

Incinerator Operator PPE Kits

Optional

Backup Spare Parts Kits

Optional

Mobile Type

Optional:Containerized/Trailer/Sledge Optional

Share this post on: