incinerators Archive

medical wasteincinerator manufacturers

medical wasteincinerator manufacturers

Model TS10 PLC Main Product List per 01 set Primary Combustion Chamber   Secondary Combustion Chamber   Smoke Filter Chamber   Incinerator PLC Control Case   Chimney:6.0Meters *(upgrade to Stainless Steel, free cost)   Italy oil/gas burner: 02 units   Oil Tank …
incinerator for hospital

incinerator for hospital

1, Using fever of gasifying unites burning technology. It applied to burn various  kinds of medical waste, such as syringes, infusion set, disposable dressing, and also  small animal, some city waste, like paper, tree leaves. 2, Closed vacuum-wide operation, applicable to treat …
Repair hospital incinerator

Repair hospital incinerator

1. Diesel primary & secondary burners with frequency of 50-60hz able to attain 8500-1200 C. 2. Blower motor/ventilation fan of 40-60 W, 110-230 V, 50 hz 3. Refractory layer per square meter. 4. Incinerator chimney segments. 5. Incinerator door gasket 6. Secondary & …
TS30 Model Waste Incinerators

TS30 Model Waste Incinerators

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet …
BANGLADESH Incinerator (Model TS20 Gas with wet scrubber)

BANGLADESH Incinerator (Model TS20 Gas with wet scrubber)

a) lncineration capacity: 75 kg/hr.– up to 100kgs/hour b) Number of combustion chamber: Two (02)—yes c) Operating temperature in primary chamber: 850±50 °C— 800°C-1000°C d) Operating temperature in secondary chamber: 1200±50 °C— 1000°C-1300°C e) Burner type: Pressure jet diesel fired—yes f) Power …
Trinidad and Tobago INCINERATOR.Q&A

Trinidad and Tobago INCINERATOR.Q&A

Question: Brick and refractories to withstand 1700°C (3092°F) Our std. high density castable refractory material is rated for 3000°F (1649°C).  There is 3100°F material available but is considerably more expensive and labour intensive to work with. The point is why?  The incinerator will …
Municipal waste incinerator

Municipal waste incinerator

General waste incinerator  – Medium Minimum Requirements: General waste incinerator Dual chamber -Medium General requirements,how to neutralize acidity in garbage incinerated waste “ Size and efficiency The proposed incinerator units must be complete and include all of the key features listed below …
Drum type incinerator

Drum type incinerator

Equipment Technical Specifications Model YD-10 Picture   Feed Capacity Average 20 kgs per feeding Burning Rate Average 10 kgs per hour Burning Time per Feed 2 hours Voltage 220V Power 0.5Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Fuel consumption (Oil) Ave. 4.2 Kgs/Hour …
CONTAINERIZED INCINERATOR

CONTAINERIZED INCINERATOR

CONTAINERIZED INCINERATOR ELECTRIC POWER SUPPLY: (GHANI 220V-50HZ-3PH, AMAL 220V-60HZ-3PH, RAS LANUF 380V_400V – 50HZ- 3PH, TIBISTI 220V-60HZ-3PH, EN-NAGA 220V- 50/60HZ- 3PH).GENERAL : A CONTAINERIZED INCINERATOR WITH DESIGHN SUITABLE FOR USE IN REMOTE AREAS SPECIFICALLY OIL AND GAS INDUSTRY.INCINERATOR UNIT SHOULD BE ABLE …
WASTE INCINERATOR TREATMENT – TS300( PLC)

WASTE INCINERATOR TREATMENT – TS300( PLC)

MOGADISHU SOMALIA WASTE INCINERATOR TREATMENT – TS300( PLC) Incinerator Items/Model HICLOVER TS300(PLC)   Burn Rate (Average) 300 kg/hour Feed Capacity(Average) 400kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 2000Liters(2.0m3) Internal Dimensions 1700x1200x1000mm Secondary Chamber 1000Liters(1.0m3) Smoke Filter Chamber Yes Feed Mode Manual Voltage …