small incinerator

  • Capacity 100 kg/hr of waste containing up to 85% moisture

 

 

  • Two fully automatic, oil fired, pressure jet burners

 

  • Panel board

 

  • Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve.

The incinerator shall be ignited with light gas oil and will automatically switch over to burning sludge or waste

oil if the required internal temperature was achieved. When burning sludge, the incinerator shall be in a position to

maintain the internal temperature by adjusting its sludge flow rate without any make up fuel. The desired internal

temperature shall be within the range of 800°C — 1000 °C and will be adjustable. Operation of the incinerator will

be completely automatic.

 

 

Control of the incinerator shall be performed via PLC which can be readily interfaced with the existing PLC system of this

sludge handling system in the Power Station. Note that the present system is an Allen Bradley SLC 500 system. The

incinerator will provide suitable fault and alarms in case of any abnormal occurrence during its operation.

Protection class of control panel shall be at least IP 54.

 

 

the entire incinerator system will be mounted on a slide which will be installed on concrete flooring. The whole

incinerator will then be attached to our existing DO and Sludge lines. A containerized alternative is also acceptable.

Note that distance allowed for installation of the incinerator unit is 7.8 metre x 4.6 metre.

Note that space earmarked for installation of the incinerator unit is 7.8 metre x 4.6 metre.

Categories: