SIEMENS Control Unit for OIl Burner LOA24.171B27 Spare Parts for Incinerator Burner
What can be burned in an incinerator?
A material commonly associated with waste incineration is municipal solid waste (MSW).
This type of waste is typically general waste such as household waste, food waste,
cardboard, and paper. All of these are safe to incinerate.

What is incinerator use for?
An incinerator is a furnace for burning waste. Modern incinerators include pollution
mitigation equipment such as flue gas cleaning. There are various types of incinerator
plant design: moving grate, fixed grate, rotary-kiln, and fluidised bed.
Incinerator Items/Model | HICLOVER TS5(PLC) | HICLOVER TS10(PLC) | HICLOVER TS20(PLC) | HICLOVER TS30(PLC) |
Burn Rate (Average) | 5-10 kg/hour | 10-20 kg/hour | 20-30 kg/hour | 30-50 kg/hour |
Feed Capacity(Average) | 10kg/feeding | 20kg/feeding | 40kg/feeding | 60kg/feeding |
Control Mode | PLC Automatic | PLC Automatic | PLC Automatic | PLC Automatic |
Combustion Chamber | 52L | 100L | 210L | 330L |
Internal Dimensions | 50x35x30cm | 50x50x40cm | 65x65x50cm | 75x75x60cm |
Secondary Chamber | 26L | 50L | 110L | 180L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual |
Voltage | 220V 2P | 220V 2P | 220V 2P | 220V 2P |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.5Kw |
Burner Type | Italy Brand | Italy Brand | Italy Brand | Italy Brand |
Oil Consumption (kg/hour) | 4 | 6 | 8 | 12 |
Gas Consumption (m3/hour) | 6.2-11.4 | 6.2-11.4 | 8-15.7 | 9.8–20 |
Temperature Monitor | Yes | Yes | Yes | Yes |
Temperature Thermometer | Corundum Probe Tube | Corundum Probe Tube | Corundum Probe Tube | Corundum Probe Tube |
Temperature Protection | Yes | Yes | Yes | Yes |
Automatic Cooling | Yes | Yes | Yes | Yes |
Automatic False Alarm | Yes | Yes | Yes | Yes |
System Testing Model | Yes | Yes | Yes | Yes |
Time Setting | Yes | Yes | Yes | Yes |
Progress Display Bar | LCD Display | LCD Display | LCD Display | LCD Display |
Oil Tank | 200L | 200L | 200L | 200L |
Oil Tank Stand | 190cm Height | 190cm Height | 190cm Height | 190cm Height |
Liquid level Display | Yes | Yes | Yes | Yes |
Feeding Door | 20x20cm | 30x30cm | 45x40cm | 55x50cm |
Chimney | 2Meter | 3Meter | 3Meter | 5Meter |
Chimney Type | Stainless Steel 304 | Stainless Steel 304 | Stainless Steel 304 | Stainless Steel 304 |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1300℃ | 1000℃-1300℃ | 1000℃-1300℃ | 1000℃-1300℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1000kg | 1500kg | 2200kg | 3000kg |
External Dimensions | 120x80x110cm | 140x90x120cm | 160x110x130cm | 175x120x140cm |
All electrical connections attached with the incinerator and other machinery should
be provided with suitable and necessary safety devices and be protected by steel
conduits, cable trays, and supports.
The manufacturer should permanently mark on the incinerator indicating:
(i) manufacturer’s name or trademark (ii) style, type, model or, date of manufacture
of the incinerator (iii) capacity in terms of net designed heat release in heat units
per timed period (i.e., British Thermal Units per hour, mega joules per hour,
kilocalories per hour).
Operations store “The unit shall be supplied with a lockable operations store,
that shall be initially supplied with the following consumables:
• A first aid kit, suitable for addressing the hazards presented by the unit.
• 5 full sets of personal protective clothing and equipment.
• Operating logbooks.
• Unit cleaning equipment.
• Unit routine maintenance equipment and associated spare parts.
• Lubricants as appropriate.
• 3 Fire extinguishers.
incinerator daito
types of medical waste
incinerator suppliers in kenya
incineration companies in ghana
incinerators for sale
• Any other consumables considered necessary by the Supplier.
The control system shall include an electronic performance monitoring and
logging system. The system shall be capable of monitoring and logging
chamber temperatures at regular intervals (not less than once per minute,
with the capacity to vary the logging frequency). The system shall include
the capacity to download the performance data by USB connection.
All the measuring devices attached with the incinerator should have
digital display and should have provision of connecting to the recording
system, which should include fuel meter and separate energy meter.
The temperature shall be determined against the inside wall of the
combustion chambers. An audible and visible alarm shall be installed to
warn the operator when the secondary temperature drops to below the required temperature.
The primary chamber must meet or exceed the following criteria:
“• Heavy steel construction.
• Fixed hearth geometry and starved air gasification operational mode.
• Hot face refractory concrete-ceramic suitable for thermal shock up to
1400 Celsius and abrasion. Minimum thickness 150mm.
• Cold face refractory lining of calcium silicate or superior material,
minimum thickness 100mm.
• Refractory lining of all the ducts shall be done with refractory castings.
Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints.
• Multiple electric ignition fuel burners designed to use automotive diesel fuel.
• Flame of the primary burner shall be oriented towards the center of the
unit which does not impinge directly on the refractory floor or wall.
The secondary burner shall be positioned in such a way that the flue gas passes through the flame.
• The unit shall prevent leakage of the hot flue gas and any backfire.
• An electrically powered fan forced air supply, with the capacity for
variation by the operator.
• Digital thermometers connected to electronic dataloggers.
The thermometers shall be located on the chamber walls away from the fuel burner.