Incineration is the most obvious solution for total destruction of municipal waste, avoidingall the direct and indirect risks associated with other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at thesame place where it was generated to avoid cross-contamination risk and to keep waste treatment costs at acceptable level.※Main Feature:
–Three Combustion Chambers or A/B Primary Combustion Chamber
— Double or Three Italy Burner
–Burning Rate: 80-800kgs per hour
–Combustion Chamber: 1.0M3-10.0M3
※Optional Function/Parts/Material/Burning Rate:
— Stainless Steel Chimney
— Dry Smoke Filter Chamber
— Chimney Height Custom Made
— Semi-Automatic Waste Feeding
— 3-Section Wet Scrubber System
— Movable Platform Feeding Door
— Additional Burner— Upgrade/Downgrade Burning RateNanjing Clover Medical Technology Co.,Ltd.Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L Smoke Filter Chamber Yes Yes Yes Yes Yes Feed Mode Manual Manual Manual Manual Manual Voltage 220V 220V 220V 220V 220V Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28 Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2 Temperature Monitor Yes Yes Yes Yes Yes Temperature Protection Yes Yes Yes Yes Yes Oil Tank 100L 100L 100L 100L 200L Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm Chimney 3Meter 3Meter 5Meter 5Meter 10Meter Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm Unit purpose Infected medical waste decontamination
Unit made from stainless steel Necessary
Decontamination process is conducted in a closed system Necessary
Waste shredding within sterilization process Necessary
Decontamination method 1No pressure;
2Moisture and heat.
Microbiological decontamination level At least 6 log10
Sterilization cycle temperature At least 1400C
The sterilization cycle time Not more than 40 min.
One cycle treated waste volume At least 100 litrų
One cycle treated waste weight At least 7 kg
Decontaminated waste must be 1Dry,
2Odorless,
3Not identifiable
The waste volume reduction after treatment At least 70%
The waste weight reduction after treatment At least 30 %
Unit control Microprocessor
Control panel Digital with touch screen
Noise level At least 80 dB
Power consumption Not more than 0,5 kWh/kg
Water consumption Not more than 0,003 m3/kg
Filtering system 1At least two-stage carbon filters;
2HEPA filter.
HEPA efficiency At least 95%
Unit capacity At least 15 kg/hr.
Impact on the environment and workers Safe, environmentally friendly
Dimensions (for particular room) 90 width (±10) x 150 depth (±10) x
120 height (±10)