A chamber of post combustion of gases
* A burner of combustion of gases,
* A device of injection of air allowing a total recombustion of gases,
* A device of air inlet of cooling of waste gases,
* A sheath of evacuation of the gases burnt.
* Carcass in strong sheet steel with assistance of link.
* Composition of the refractory;
Refractory concrete:
Thickness: ≥150 mm
Character: 65% of Al203
Insulate in fibrous panel:
Thickness: ≥85 mm
Character: Calcium
* Burner with fuel, mono-bloc casting directing type with horizontal flame, lighting and security of electronic ignition,
permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* A secondary injection of air to guarantee perfect oxygen content. A control box ensuring the complete cycle of combustion. Fan:
* Electro-ventilator distributing the secondary air, the regulation of the air flow being completed by valves and
after the control of the automatic cycle. Controls and regulations:
Control box watertight to dust, including:
* A switch circuit breaker for each engine (ventilators and burners).
* A timer with adjustable temporization for the regulation of every burner.
* A regulator with digital viewing for the temperature of combustion.
* A regulator with digital viewing for the temperature of postcombustion.
* Electric box.
batch de ashing.
22. The supplier must give batches of spare pieces of first urgency and consumable of the incinerator.
23. The installed incinerator must bear a 1 year guarantee.
24. The supplier shall perforn an onsite installation of the incinerator.
- The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual
the factory; it’ll consist of curative and preventive maintenance, and the usage of machine, etc
- Process Filtering system : Scruber to be mentionned as optional
- Emission Standards Compliance: BS 3316 or équivalent standard
- Capacity to treat Plastic: Not less than 40% by weight
- CE Manufacturing Compliance: BS EN 746-2-1997
22.The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
23.The installed incinerator must bear a one year guarantee.
24.The supplier shall perforn an onsite installation of the incinerator.
- The technical training of operators will have to be provided and given by a technician from
the factory; it will consist of curative and preventive maintenance, and the use of machine, etc