Product Description
Technology Respond(FAQ)
Q: What is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid waste and gas waste. GB18484-2001. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Incinerator combustion chamber photograph, incinerator crematory, incinerator dealers, incinerator gas fired, incinerator for medical waste, incinerator for medicial waste, Actual combustion time per day is about 16 hours. The life of incinerator between 5-10 year based on use.
Generally, we proposal little laboratory, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed at the hospital, that's mean you need 1 incinerator capacity around 400kgs each day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators easy to setup and operation. Client can send people come to our factory to learn operation and installation. Generally, We do not send engineer to local site if not request. The dispatch cost is additional according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi level. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control manner is common control instance. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, use situation.
One person can service 02 device incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, and understand risk of medical waste to protect worker self with necessary protection element.
Q: The Residency period in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |