Incinerator Items/Model |
HICLOVER TS30(PLC) |
HICLOVER TS50(PLC) |
HICLOVER TS100(PLC) |
|
Burn Rate (Average) |
30-50 kg/hour |
50-100 kg/hour |
100-150 kg/hour |
|
Feed Capacity(Average) |
60kg/feeding |
100kg/feeding |
350kg/feeding |
|
Control Mode |
PLC Automatic |
PLC Automatic |
PLC Automatic |
|
Primary Combustion Chamber |
330L(0.33M3) |
560L(0.56M3) |
1810L(1.81M3) |
|
Internal Dimensions |
75x75x60cm |
100x80x70cm |
165x110x100cm |
|
Secondary Chamber |
180L |
280L |
660L |
|
Smoke Filter Chamber |
Yes |
Yes |
Yes |
|
Feed Mode |
Manual |
Manual |
Manual |
|
Voltage |
380V±10%, 50Hz |
380V±10%, 50Hz |
380V±10%, 50Hz |
|
Power |
5.0Kw |
6.0Kw |
8.0Kw |
|
Burner Type |
Italy Brand |
Italy Brand |
Italy Brand |
|
Oil Consumption (kg/hour) |
12 |
12 |
16 |
|
N.Gas Consumption (m3n/hour) |
16 |
21 |
25 |
|
Temperature Monitor |
Yes |
Yes |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
Corundum Probe Tube, 1400℃Rate. |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
Yes |
Yes |
|
Automatic Cooling |
Yes |
Yes |
Yes |
|
Automatic False Alarm |
Yes |
Yes |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
Yes |
Yes |
|
System Testing Model |
Yes |
Yes |
Yes |
|
Time Setting |
Yes |
Yes |
Yes |
|
Progress Display Bar |
LCD Display |
LCD Display |
LCD Display |
|
Oil Tank |
200L |
200L |
200L |
|
Oil Tank Stand |
190cm Height |
190cm Height |
190cm Height |
|
Liquid level Display |
Yes |
Yes |
Yes |
|
Feeding Door |
40x40cm |
50x50cm |
60x70cm |
|
Chimney |
10Meter |
10Meter |
10Meter |
|
Chimney Type |
Stainless Steel 304 |
Stainless Steel 304 |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
800℃–1000℃ |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
1000℃-1300℃ |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
2.0 Sec. |
2.0 Sec. |
|
Gross Weight |
4000kg |
6000kg |
8000kg |
|
External Dimensions |
200x140x160cm |
250x150x180cm |
280 x 180 x 200cm |
|
1st. Chamber Composition Hot Face |
Thickness: ≥180 mm |
Thickness: ≥180 mm |
Thickness: ≥180 mm |
|
55% of Al203 |
55% of Al203 |
55% of Al203 |
||
1750°C Grade |
1750°C Grade |
1750°C Grade |
||
2nd. Chamber Composition Hot Face |
Thickness: ≥180 mm |
Thickness: ≥180 mm |
Thickness: ≥180 mm |
|
75% of Al203 |
75% of Al203 |
75% of Al203 |
||
1790°C Grade |
1790°C Grade |
1790°C Grade |
||
Chamber Cold Face Material |
High Rate Refractory Ceramic Fiber |
High Rate Refractory Ceramic Fiber |
High Rate Refractory Ceramic Fiber |
|
Other Parts Hot Face Refractory |
Heavy Duty with steel fiber |
Heavy Duty with steel fiber |
Heavy Duty with steel fiber |
|
Burner operation |
Automatic On/Off |
Automatic On/Off |
Automatic On/Off |
|
Dry Scrubber |
Including |
Including |
Including |
|
Wet Scrubber |
Optional |
Optional |
Optional |
|
Top Loading Door |
Optional |
Optional |
Optional |
|
Paint for outside face |
250°C Grade |
250°C Grade |
250°C Grade |
|
Sealing Material |
Refractory Ceramic Fiber |
Refractory Ceramic Fiber |
Refractory Ceramic Fiber |
|
Upgrade Containerized Mobile Type |
Optional |
Optional |
Optional |
|
CE Certificate |
CE(2006/42/EC,2014/30/EU |
CE(2006/42/EC,2014/30/EU |
CE(2006/42/EC,2014/30/EU |
|
ISO Certificate |
ISO9001:2015 |
ISO9001:2015 |
ISO9001:2015 |
|
High-tech Enterprise Certificate |
Yes |
Yes |
Yes |

The Incinerator (waste management system ) is a turn-key project which will compromise a hospital grade incinerator, allied accessories for proper disposal of hospital solid waste material and imputed human organs.
The incinerator shall also be suitable for plastic, paper, textile and rubber dry and wet infectious waste of the hospital. The unit shall be of high performance to
be opened continuously for at least 08 C 12 hours daily. The Primary source of fuel will be natural gas (must be compatible with LPG as backup source with vaporizers)
based on pyrolytic
combustion with smokeless emissions. For ensuring the clean environment, it should strictly comply with EPA standards having EIA certifications
The incinerator system should be based on at least design and recently manufactured having following specifications:-
(1) Burning Capacity. Continuous feeding and burning capacity of 50-60 kg/ hour or better having volume of 500 liters or more. YES, 50-100kgs/hr. 560 Liters
(2) Construction
(a) Primary Chamber
i. Rectangular shape dual chamber construction YES
ii. The feeding door should be in accordance to load size and should be front loaded or side loaded (Manual/ Automatic). YES
iii. The steel sheet shall be at least 6-8mm thick & 10-12mm or more from front with Heat resistant paint. YES. 8MM MAINBODY. 15MM PARTIAL STRENGTHENING
iv. The internal surface of the incinerator shall be lined with non-cracking refractory bricks (high content of Aluminum or suitable material) along with isolation bricks to withstand a temperature of 1400°C backed by thermal insulation. HOT FACE, HIGH ALUMINUM FIREBRICK 55% OF AL203,1750°C GRADE. CODE FACE, HIGH RATE REFRACTORY CERAMIC FIBER, 1050°C GRADE.
(b) Post Chamber. Post combustion chamber is lined with high thermal insulating materials with a thickness of 150mm or more of refractory bricks and 85mm of insulator. Hot Face, 180mm, High aluminum firebrick 55% of Al203,1750°C Grade. Code Face, 100mm, High Rate Refractory Ceramic Fiber, 1050°C Grade.
(c) Chimney
i. Chimney should be made of stainless steel flanged section. YES
ii. Height of chimney should be 8-12 meters YES – 10 METERS
iii. Chimney should be fitted with sampling port for the collection and measuring of gas samples. YES
(3) Technical Specifications
(a) Primary Chamber (Combustion)
i. Blower centrifugal fan(s) shall be provided to inject air to burn the waste and gases in combustion chamber. YES
ii. Automatic electronically controlled air distribution and regulation system. YES
iii. The temperature should not be less than 850°C. AVE.900C
iv. A see through window with protection flap for inspection of burners flame should be provided. YES
v. Thermocouple/sensors to monitor the temperature of the primary chamber. YES
vi. Two medium electricity operated natural gas burners or one large with the provision to operate in standby LPG fuel with burning power not less than 250 kw YES
(b) Secondary Chamber (Post Combustion)
i. The post combustion chamber for flue gases with retention time of 1 to 2 seconds to burn further for ensuring smokeless exhaust emissions. YES
ii. Automatic electronically controlled air distribution and regulation system. YES
iii. The temperature should not be less than 850°C or better. AVE.1100C
iv. Two medium electrically operated natural gas or more large with the provision to operate on standby LPG fuel. YES
v. Thermocouples/sensors to monitor the temperature of the secondary chamber. YES
(4) Burners
(a) Combustion and post combustion chambers with electrically operated burners suitable for natural gas operation as well as standby LPG fuel . YES
(b) Automatic closing of burners with opening of respective chambers door. YES, Automatic Protection Operator(APO)
(c) Electrical safeties to prevent startup of burner. YES
(5) Standby LPG Fuel. There should be manifold system for reserve LPG cylinders having sufficient capacity to run the incinerator for at least 12 hrs. YES
(6) Freed System
(a) Manual Feeding system with continuous intervals. YES
(b) Calorific value of the feeding waste: 3.5 to 4 KW / kg better YES
(7) Gas Washer/ Wet Scrubber
(a) Mild steel integrated pass through type gas washing systems. YES, Stainless Steel
(b) Water saving system with re-circulating system. YES
(8) Water Treatment. Water treatment unit to treat the water used for gas washing before opening it into main drain. YES
(9) Controls
(a) Microprocessor/PLC based control box with hinged sealed door. YES
(b) Pre-installed control circuitry should be rugged enough to withstand the temperature effect of the incinerator. YES
(c) It should house the ignition burner timer, feed interval timer , shut down timer post combustion chamber temperature controller, and controls for burner, blower fans, gas washer etc. YES
(d) Digital display of temperature and set timing parameters. YES
(e) The control panel shall be fitted with a functional synoptic view showing the operating situation of the installation YES
(f) Emergency Shutdown button for shutting it off in case of emergency. YES
(10)The temperature of outer surface of the burning chambers should not rise beyond a temperature of 60°C after operation of several hours. YES
(11)Smokeless emission for at least 98% of running time. YES
Categories: