crematorium manufacturers

Doors

The doors shall be hinged on the right hand side and can be easily opened and closed. Incinerator will NOT incorporate automatic doors.

 

Stack

The stack shall be fabricated from pre-determined thickness stainless steel plate suitably flanged for connection.

 

Combustion Air Blower

A combustion air blower shall be of steel construction type with built-in air damper regulation shall be provided. The

impeller shall be of the radial blade design and all rotating elements shall be dynamically balanced.

 

Burners

Burners fitted shall be of packaged fuel oil fired types. Primary chamber shall be fitted with an on/off type burner

while the secondary chamber shall be fitted with a high/low type burner. The burners shall each have a maximum score

of300,000 kJ/hr.

 

Controls

A control system shall be provided to control all functions of the primary and secondary chambers such as combustion

air distribution and burner control. It will comprise of PLC, temperature controllers, timers, relays and switches to

offer automatic operation of the entire system. All switches and controls shall be mounted in an IP 55 rated control

panel.

 

Power Supply

The incinerators will have a power source of 240/415 volts, 50 Hz AC. All electrical works shall conform to SAA Wiring

Rules SA 3000 and be subject to PNG Power regulations.

The incinerators shall have a power supply of 240/415 volts, 50 Hz AC. All electrical works shall conform to SAA Wiring

Rules SA 3000 and be subject to PNG Power regulations.