{"id":3856,"date":"2022-04-19T13:43:59","date_gmt":"2022-04-19T13:43:59","guid":{"rendered":"https:\/\/www.hiclover.com\/?p=3856"},"modified":"2022-04-19T13:43:59","modified_gmt":"2022-04-19T13:43:59","slug":"numerous-sorts-of-burners","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/backup\/numerous-sorts-of-burners\/","title":{"rendered":"Numerous Sorts Of Burners"},"content":{"rendered":"<div class=\"topad\">\n\t\t\t\t\t\t\t\t\t\t<script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js\"><\/script><\/p>\n<\/div>\n<p>  Heater design B. Burn Price 150kg\/h minimal.<br \/>\n10m Hose pipe Pipeline, show duration.<br \/>\n10m Tube Pipe, recommend length.<br \/>\nMinimum leave rate of the discharges not less than 10 metres\/second<br \/>\nExtra Chamber.<br \/>\n1000 Litre Fuel Storage Tank + Pipeline System, indicate quantity.<br \/>\n2nd Chamber.<br \/>\nGuarantee, reveal no of years  <\/p>\n<p>  Heater variation C.<br \/>\nMobile Incinerator version E. Burn Price 50kg\/h minimal.  Weight (kg), please show:.<br \/>\nService guarantee, indicate no of years  <\/p>\n<p>  Whole lot 4&#8211; &#8211; High Temperature Waste Incinerator.<br \/>\nService guarantee, reveal no of years  <\/p>\n<p>  Great deal 5&#8211; &#8211; Mobile Burner.<br \/>\nMobile Heater design F. Burn Price 100kg\/h minimal.  Weight( kg), please recommend:.<br \/>\nAdditional Chamber.<br \/>\nMinimum working temperature 1200 \u00b0 C, please show.\n<\/p>\n<p>  contaminated materials high temperature burners for the treatment of contaminateds materials.  The waste will surely be blended, such as medical, oily wastes, forests in addition to lab wastes.  Key burning<br \/>\nGas Retention Time &#8211; &#8211; &#8211; &#8211; 2 Seconds.  Power Supply &#8211; for &#8211; Control Box &#8211; 220V-240V 50Hz solitary phase.<br \/>\nAdditional chimney expansion, recommend altitude  <\/p>\n<p>\n10m Tube Pipe, indicate span.<br \/>\nDiesel\/LPG\/LNG burning primary burning chamber\/primary burning place<br \/>\nGeneral<br \/>\n10m Tube Pipeline, indicate size.<br \/>\nGas Retention Time &#8211; &#8211; 2 Secs.  Diesel\/LPG\/LNG, please indicate.  Minimum working temperature level 920 \u00b0 C, please indicate.<br \/>\nBurn Rate 100kg\/h minimal.<br \/>\nAdded smokeshaft growth, reveal elevation.<br \/>\nSmokeshaft with a minimum altitude of 4 meters above ground level<br \/>\nTemperature level Cautions<br \/>\n10m Tube Pipeline, indicate size.  I000 Litre Gas Container+ Pipeline System, show volume.  Included smokeshaft expansion<br \/>\nWeight (kg), please show:.<br \/>\nExtra burning<br \/>\nSecond Chamber.<br \/>\nGas Retention Time 2 Seconds.<br \/>\nHTW Incinerator layout D. Burn Cost &#8211; &#8211; 150kg\/hour minimal.{<br \/>\n(adsbygoogle = window.adsbygoogle || []).push({});|}<br \/>\nAdditional smokeshaft development, suggest altitude.<br \/>\nAssurance, show no of years  <\/p>\n<p>  Great deal 7&#8211; &#8211; Heat Waste Mobile Burner.<br \/>\nChimney<br \/>\nGas Retention Time &#8211; &#8211; &#8211; &#8211; 2 Secs.   Power Supply for Control Box &#8211; &#8211; &#8211; &#8211; 220V-240V 50Hz lone stage.<br \/>\n Gas &#8211; Diesel\/LPG\/LNG, please show.  Minimum running temperature amount 850 \u00b0 C, please indicate.<br \/>\n1000 Litre Gas Storage Tank + Pipe System, indicate volume.<br \/>\nGas Diesel\/LPG\/LNG, please indicate.<br \/>\nControl box which could be separated and positioned on separate stand in the very least 1.5 meters from incinerator at around 1.6 meter height  <\/p>\n<div class=\"bottomad\">\n\t\t\t\t\t\t\t\t\t\t<script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js\"><\/script><\/p>\n<p>  Burner variation A.<br \/>\nGas Retention Time &#8211; &#8211; &#8211; &#8211; 2 Secs.  Gas &#8211; Diesel\/LPG\/LNG, please indicate &#8211;.   Minimum running temperature 850 \u00b0 C, please indicate.  1 year Spare Elements Package for full maintainability.<br \/>\nMinimum working temperature amount 1200 \u00b0 C, please show.<br \/>\nHTW Mobile Incinerator design G.<br \/>\nHouse time in the second chamber very little less than 2 secs<br \/>\nPower Supply for Control Box 220V-240V, single stage 50-60Hz.<br \/>\nAdditional smokeshaft growth, suggest altitude.<br \/>\nMinimum running temperature 920 \u00b0 C, please show.<br \/>\nAssurance, suggest no of years  <\/p><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Heater design B. Burn Price 150kg\/h minimal. 10m Hose pipe Pipeline, show duration. 10m Tube Pipe, recommend length. Minimum leave rate of the discharges not less than 10 metres\/second Extra Chamber. 1000 Litre Fuel Storage Tank + Pipeline System, indicate quantity. 2nd Chamber. Guarantee, reveal no of years Heater variation C. Mobile Incinerator version E. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2015,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[20],"tags":[],"class_list":["post-3856","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-waste-incinerator"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/3856","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/comments?post=3856"}],"version-history":[{"count":0,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/3856\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media\/2015"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media?parent=3856"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/categories?post=3856"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/tags?post=3856"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}