{"id":3795,"date":"2022-03-28T01:37:24","date_gmt":"2022-03-28T01:37:24","guid":{"rendered":"https:\/\/www.hiclover.com\/?p=3795"},"modified":"2022-03-28T01:37:24","modified_gmt":"2022-03-28T01:37:24","slug":"small-incinerator-for-sale","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/backup\/small-incinerator-for-sale\/","title":{"rendered":"small incinerator for sale"},"content":{"rendered":"<p> Sterilization time: approx. 30 minutes at 121\u25e6C\/1.1 Tavern or approx\u00a0 15 minutes at 132\u25e6C\/2.5 Tavern to reach 6log10 <\/p>\n<p> sterility <\/p>\n<p> \uf0b7Fragmentation within the chamber: Heavy duty with maximum size of final product <20 cm.  <\/p>\n<p> \uf0b7Volume reduction of the waste after processing: by 60-80% through complete waste dehydration including liquid <\/p>\n<p> content of this waste <\/p>\n<p> \uf0b7All actions after loading for sterilization, fragmentation of merchandise is to be happened in the identical chamber\/vessel <\/p>\n<p> \uf0b7Pre or Post-air evacuation should not be necessary or used <\/p>\n<p> \uf0b7Exhaust air quality: Does not need any venting for odor control <\/p>\n<p> \uf0b7Operating System: Fully automatic with manual over-ride.  <\/p>\n<p> \uf0b7The sterilization vessel MUST be a double walled (jacketed) cylindrical vessel.  <\/p>\n<p> \uf0b7Pre-shredding of infectious waste should not be accepted, the fragmentation should occur safely within the scaled vessel <\/p>\n<p> continuously.  <\/p>\n<p> \uf0b7The sterilization vessel\/chamber must be fitted with a motor driven shaft to which a heavy duty grinder (fragmenting <\/p>\n<p> arm) is attached within the vessel to make an unrecognizable size of this waste product <\/p>\n<p> \uf0b7The fragmenting are must rotate to agitated continuously through the heating and sterilization cycle to guarantee <\/p>\n<p> that the fragmented &#038; sterile wastes (including sharps and liquids) are vulnerable evenly to sterilization temperature <\/p>\n<p> and strain.  <\/p>\n<p> \uf0b7Steam heat ought to be applied to the coat only, while the agitated waste absorbs the heat from the coat and makes <\/p>\n<p> its own steam from its moisture content.  <\/p>\n<p> \uf0b7Should not need for special autoclave bags- easy bag or box ought to be workable <\/p>\n<p> \uf0b7MUST not need for pre-treatment of this waste.  <\/p>\n<p> \uf0b7Liquids and gases MUST stay locked within the vessel until sterilization is complete-nothing ought to be vacuumed or <\/p>\n<p> pumped out in its infected state.  <\/p>\n<p> \uf0b7Jacket steam heat to dehydrate the waste completely no matter its original water content.  <\/p>\n<p> \uf0b7All the hot condensate from the coat is recycled, which makes the chip very economical to operate <\/p>\n<p> \uf0b7All particles of this waste should achieve a high level of sterilization instead of just&#8221;disinfection&#8221; because of the <\/p>\n<p> constant agitation.  <\/p>\n<p> Description of the Remedy Cycle of the chip <\/p>\n<p> I)Loading <\/p>\n<p> \uf0a7The waste has to be loaded by falling bagged and or boxed waste to the open loading door on the vessel.  <\/p>\n<p> \uf0a7The loading door ought to be mounted at an angle on the top side of the vessel with suitably sized to accommodate the <\/p>\n<p> infectious wastes for which it&#8217;s intended <\/p>\n<p> \uf0a7Over-loading or loading too tightly should not be an issue with this process, and hence no need of the special <\/p>\n<p> operator ability.  <\/p>\n<p> ii)Heat &#8211;up and fragmentation <\/p>\n<p> \uf0a7After loading, the vessel door is to be closed, and the outer coat of this vessel is to be automatically filled <\/p>\n<p> with high temperature steam, which should act as the principal heating medium for heating the waste <\/p>\n<p> \uf0a7in this heating cycle, the shaft and mixing arms ought to rotate continuously, causing the waste to be fragmented <\/p>\n<p> and always tumbled from the hot vessel walls.  <\/p>\n<p> \uf0a7At this point, the waste is broken into small fragments, and all material heats up quickly, being evenly and <\/p>\n<p> thoroughly exposed to the hot inner surfaces.  The moisture content of the waste will turn into steam, and the vessel <\/p>\n<p> will begin to pressurize.   If there insufficient moisture from the waste to pressurize the <\/p>\n<p> vessel, a small amount of steam is to be automatically added until the desired pressure is reached.  <\/p>\n<p> \uf0a7At the end of the period, the right sterilization temperature and should be reached, and the sterilization period <\/p>\n<p> must begin.  <\/p>\n<p> iii)Sterilization interval <\/p>\n<p> \uf0a7the total amount of steam fed to the outer coat is to be regulated to keep the desired temperature &#038; pressure of this <\/p>\n<p> inner vessel.  <\/p>\n<p> \uf0a7The mixing arms (grinder)\u00a0 MUST continue to rotate during this cycle to ensure sterilization pressure and <\/p>\n<p> temperature for many wastes.   <\/p>\n<p> iv)De-pressurization <\/p>\n<p> \uf0a7Following the treatment time, the steam to the coat should stay on, and the internal vessel is to <\/p>\n<p> be vented through a condenser, and de-pressurized.  Thus, the waste loses its water content <\/p>\n<p> through a combination of heat input from the coat and flashing of water because of <\/p>\n<p> depressurization.  <\/p>\n<p> v)De-hydration <\/p>\n<p> \uf0a7Further dehydration is to be achieved by keeping heat input and mixing-almost complete dryness ought to be achieved.  <\/p>\n<p>\uf0a7The mixing arms (grinder)\u00a0 MUST continue to rotate throughout this cycle to ensure even sterilization pressure and<\/p>\n<p>temperature for all wastes.<\/p>\n<p>\uf0a7The treatment time should be either 15 minutes at 132\u25e6C OR 30 minutes at 121\u25e6C\u00a0 to achieve level 6log10 sterilization<\/p>\n<p>\uf0a7The intense subjugation of the waste to high temperature and pressure moisture in a dynamic environment should also<\/p>\n<p>cause the waste to hydrolyze, that is a rapid decomposition of organic material.<\/p>\n<p>iv)De-pressurization<\/p>\n<p>\uf0a7After the treatment time , the steam to the jacket should remain on, and the internal vessel is to<\/p>\n<p>be vented through a condenser, and de-pressurized. Thus, the waste loses its water content<\/p>\n<p>through a combination of heat input from the jacket and flashing of water due to<\/p>\n<p>depressurization.<\/p>\n<p>v)De-hydration<\/p>\n<p>\uf0a7Further dehydration is to be achieved by maintaining heat input and mixing-almost total dryness should be achieved.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sterilization time: approx. 30 minutes at 121\u25e6C\/1.1 Tavern or approx\u00a0 15 minutes at 132\u25e6C\/2.5 Tavern to reach 6log10 sterility \uf0b7Fragmentation within the chamber: Heavy duty with maximum size of final product<\/p>\n","protected":false},"author":1,"featured_media":2021,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[20],"tags":[],"class_list":["post-3795","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-waste-incinerator"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/3795","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/comments?post=3795"}],"version-history":[{"count":0,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/3795\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media\/2021"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media?parent=3795"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/categories?post=3795"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/tags?post=3795"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}