{"id":3793,"date":"2022-03-27T01:36:56","date_gmt":"2022-03-27T01:36:56","guid":{"rendered":"https:\/\/www.hiclover.com\/?p=3793"},"modified":"2022-03-27T01:36:56","modified_gmt":"2022-03-27T01:36:56","slug":"incinerator-for-medical-waste-2","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/backup\/incinerator-for-medical-waste-2\/","title":{"rendered":"incinerator for medical waste"},"content":{"rendered":"<p> \uf0a7Battery Charger: Must be built in battery charger, rectifier type with transformer, circuit breaker and overload <\/p>\n<p> protection plugs into any 220VAC outlet.  <\/p>\n<p> \uf0a7Steering: A pallet truck style steer handle for easy maneuverability.  <\/p>\n<p> \uf0a7Wheels: approx. 5&#8243; phenolic rear casters for steering and approx. 4&#8243; phenolic wheels with roller bearings situated <\/p>\n<p> from the straddle legs.  <\/p>\n<p> \uf0a7Brake: A hand controlled floor lock brake that secures the till in place.  <\/p>\n<p> Characteristics: <\/p>\n<p> \uf0a7Load capacity: approx 1,500 Ibs <\/p>\n<p> \uf0a7Load centre: approx 24 inch <\/p>\n<p> \uf0a7Raised fork height: to match customer needs <\/p>\n<p> \uf0a7Overall mast height: to match customer needs <\/p>\n<p> \uf0a7Lowered height: minimum 4.0 in. <\/p>\n<p> \uf0a7Fixed fork width: approx 7 inch <\/p>\n<p> \uf0a7Fork length: approx 42 inch <\/p>\n<p> \uf0a7Platform of approx. 25&#8243; x 25&#8243; <\/p>\n<p> \uf0a7Overall width approx 25 inch <\/p>\n<p> \uf0a7Castors: approx 5 inch phenolic <\/p>\n<p> \uf0a7Front wheel: approx 4 inch phenolic <\/p>\n<p> (G)Technical Specification of Spore tester <\/p>\n<p> Features and Specifications <\/p>\n<p> \uf0a7it&#8217;s an Auto-reader for Bacillus Stearothermophilus to check the spore in the discharge after treatment <\/p>\n<p> (Sterilization) of the waste.  <\/p>\n<p> \uf0a7Should be quite a Accurate, dependable and easy-to &#8211;use\u00a0 units for studying Rapid Readout Biological Indicators (RRBI) <\/p>\n<p> for Steam Sterilizer <\/p>\n<p> \uf0a7Automatically reads index outcomes.  <\/p>\n<p> \uf0a7There should be a red plus (+) light to signify sterilization failure and a green negative (-) light to verify <\/p>\n<p> the sterilization conditions are met.  <\/p>\n<p> \uf0a7Available alarm in case of positive detected and RRBI is removed from the reader before final results have been <\/p>\n<p> detected.  <\/p>\n<p> \uf0a7There should also be a Buzzer alarm OFF button.  <\/p>\n<p> \uf0a7The unit should be maintenance-free equipment and there shouldn&#8217;t be any light bulbs to replace for maintenance.  <\/p>\n<p> \uf0a7At least 12 Incubation\/reader wells <\/p>\n<p> \uf0a7A crushing well <\/p>\n<p> \uf0a7Digital screen <\/p>\n<p> \uf0a7A Press-button by pressing that, the incubation time remaining for each individual incubation\/reader well that <\/p>\n<p> contains a RRBI will be displayed.  <\/p>\n<p> \uf0a7Power: 220 VAC, 50Hz <\/p>\n<p> Accessories to be included <\/p>\n<p> \uf0a7Samples\/kits-100 pcs <\/p>\n<p> Documents to be filed as follows- <\/p>\n<p> \uf0a7Fabricators accreditations <\/p>\n<p> \uf0a7Test Report to prove ZERO harmful emission level provided as samples from other installations <\/p>\n<p> \uf0a7Test report to demonstrate sterility achieved at 6log10 degree to be given upon commissioning report and validation <\/p>\n<p> Technical proposal should include: <\/p>\n<p> \uf0a7The hospital should offer the essential space; construction &#038; infrastructure; Sufficient Power, steam supply and <\/p>\n<p> connection up to space; water &#038; Sewage line to the space.  <\/p>\n<p> \uf0a7Room Preparation: Preparation, Renovation &#038; Modification of this room is providers responsibility <\/p>\n<p> \uf0a7The supplier should submit the essential drawing(s) showing space requirement (room size\u00a0 (L x W x H ), dimensions <\/p>\n<p> of chips &#038; ancillary equipment.  <\/p>\n<p> \uf0a7Provider must give the suggestion of the complete power requirement of the entire until and on the hospital will <\/p>\n<p> ensure the power supply.  However, connections\u00a0 within the room is providers responsibility <\/p>\n<p> \uf0a7The connection\/fittings from the chip and ancillary equipment to sewage and water line is providers <\/p>\n<p> duty <\/p>\n<p> \uf0a7A detailed training proposal including the term of staff training on how to operate and take care of the processor.  <\/p>\n<p> \uf0a7A detailed maintenance schedule.  <\/p>\n<p> \uf0a7List of Spare components and accessories required for maintenance of this system <\/p>\n<p> Warranty &#038; After Sales Services: <\/p>\n<p> \uf0a7Warranty period will be minimal 03 (three) years or as offered by the manufacturer which comes later.  <\/p>\n<p> \uf0a7Warranty period will be counted from the date of handing over of machine to the consumer in working condition i.e. <\/p>\n<p> date of commission <\/p>\n<p> \uf0a7In warranty period the supplier need to offer all maintenance &#038; repair services.  <\/p>\n<p> \uf0a7Brach time won&#8217;t be counted in warranty period.  <\/p>\n<p> \uf0a7At last 10 year ago up services (including warranty period ) has to be ensured by the supplier.  <\/p>\n<p> \uf0a7The repair\/maintenance work should be carried out within 72 hours after getting request for such from the consumer.  <\/p>\n<p> Quality Standard: CE\/FDA certification of the offered item must be filed with the offer <\/p>\n<p> \uf0a7For confirmation of this certification bidder must submit the followings:- <\/p>\n<p> I)Mailing Address of the issuer of this certificate <\/p>\n<p> ii)Web-site, email address &#038; Fax &#038; Telephone Number of the issuer <\/p>\n<p> \uf0a7The bid will be non-responsive if:- <\/p>\n<p> I)The certificate cannot be reached <\/p>\n<p> ii)The issuer fails to authentic the certification within the bid validity <\/p>\n<p> iii)The issuer confirms that the submitted certification is faulty in terms of authenticity or validity.  <\/p>\n<p> \uf0a7Failure to establish the authenticity\u00a0 of the certification the bidder is liable to render the bid non-responsive and <\/p>\n<p> the bidder open to act in the line with applicable regulations and act.  <\/p>\n<p> oOriginal catalogue has to be filed <\/p>\n<p> oOriginal information sheet must be submitted.  <\/p>\n<p>iii)The issuer confirms that the submitted certificate is defective in terms of authenticity or validity.<\/p>\n<p>\uf0a7Failure to establish the authenticity\u00a0 of the certificate the bidder is liable to render the bid non-responsive and<\/p>\n<p>the bidder open to action in the line with applicable regulations and act.<\/p>\n<p>oOriginal catalogue must be submitted<\/p>\n<p>oOriginal data sheet must be submitted.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\uf0a7Battery Charger: Must be built in battery charger, rectifier type with transformer, circuit breaker and overload protection plugs into any 220VAC outlet. \uf0a7Steering: A pallet truck style steer handle for easy maneuverability. \uf0a7Wheels: approx. 5&#8243; phenolic rear casters for steering and approx. 4&#8243; phenolic wheels with roller bearings situated from the straddle legs. \uf0a7Brake: A [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2021,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[20],"tags":[],"class_list":["post-3793","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-waste-incinerator"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/3793","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/comments?post=3793"}],"version-history":[{"count":0,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/3793\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media\/2021"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media?parent=3793"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/categories?post=3793"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/tags?post=3793"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}