{"id":2960,"date":"2021-11-29T00:59:17","date_gmt":"2021-11-29T00:59:17","guid":{"rendered":"https:\/\/www.hiclover.com\/?p=2960"},"modified":"2021-11-29T00:59:17","modified_gmt":"2021-11-29T00:59:17","slug":"300-kg-incinerator","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/backup\/300-kg-incinerator\/","title":{"rendered":"300 kg incinerator"},"content":{"rendered":"<ol>\n<li>i) Patient and operator safety and system performance should not be adversely affected by fluid spills.<\/li>\n<li>ii) If the unit is affected, it should fail safely.<\/li>\n<\/ol>\n<p> &nbsp; <\/p>\n<ol>\n<li>c) Overcurrent Protection<\/li>\n<li>i) Loss of power to other equipment on the same branch circuit due to internal equipment faults should be<\/li>\n<\/ol>\n<p> prevented by using fuses or circuit breakers which are clearly labeled and easy to replace or reset.  <\/p>\n<ol>\n<li>ii) If fuses are used, a spare fuse should be provided in a labeled holder located next to the main fuse holder.<\/li>\n<\/ol>\n<p> Permanent markings near each fuse holder must indicate fuse ratings.  <\/p>\n<p> &nbsp; <\/p>\n<ol>\n<li>d) Line Voltage Variation<\/li>\n<li>i) The unit should operate satisfactorily at line voltages from -12.5% to +8%<\/li>\n<\/ol>\n<p> of the nominal line voltage of 220Volts.  <\/p>\n<ol start=\"12\">\n<li>ii) The unit should not be damaged by voltages from -21% to +12.5% of the nominal line voltage of 220Volts.<\/li>\n<\/ol>\n<p> &nbsp; <\/p>\n<p> &nbsp; <\/p>\n<p> &nbsp; <\/p>\n<ol>\n<li>e) Electromagnetic Interference (EMI)<\/li>\n<li>i) The unit&#8217;s performance should not be affected by EMI radiated or conducted through the power lines from another<\/li>\n<\/ol>\n<p> device.  <\/p>\n<ol>\n<li>ii) If the unit is affected, it should fail safely.<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>i) Patient and operator safety and system performance should not be adversely affected by fluid spills. ii) If the unit is affected, it should fail safely. &nbsp; c) Overcurrent Protection i) Loss of power to other equipment on the same branch circuit due to internal equipment faults should be prevented by using fuses or circuit [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2016,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[20],"tags":[],"class_list":["post-2960","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-waste-incinerator"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/2960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/comments?post=2960"}],"version-history":[{"count":0,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/posts\/2960\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media\/2016"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/media?parent=2960"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/categories?post=2960"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/backup\/wp-json\/wp\/v2\/tags?post=2960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}