Items/Model TS50(PLC) Picture Principle Medical Waste Incineration,dual chamber incinerator Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Consumption (kg/hour) […]
Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700Liters (2.7m3) Internal Dimensions 190x120x120cm Secondary Chamber 1300Liters (1.3m3) Smoke Filter Chamber Dry Scrubber Chamber Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (kg/hour) Average […]
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Mobile Type Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. HICLOVER […]
Items/Model TS800 Picture Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control Mode Electric Control Combustion Chamber 3000Liter Internal Dimensions 300*100*100 cm Secondary Chamber *** Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) ***waste to energy plants cost Gas Consumption […]
Item Specification Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Wet Scrubber( Washing Tower) Incinerator Control Case […]
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. bio medical […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Equipment Technical Specifications Model TS30S Picture Feed Capacity 78 Liters for primary chamber Burning Rate Average 30 kgs per hour Burning Time per Feed 0.5 hour Voltage 220V Power 0.5Kw Fuel Diesel oil Burner Diesel Oil Burner, 2 sets Feed Mode Manual Fuel consumption […]
Items/Model TS75 Picture Principle Solid Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 600L Internal Dimensions 100x60x100cm Secondary Chamber 300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (L/Hour) 15-20 Natural […]
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against […]
Waste Disposal Methods in Hospital • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required. The automated burn completion and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as […]
Model A1500(Movable platform & Auto. Door) Picture Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil/ Natural Gas/LPG […]
The equipment proposed shall be an incinerator specialised for Medical Wastes. Medical waste may consist of discarded materials or equipment contaminated with blood and its derivatives, other body fluids or excreta from infected patients with hazardous communicable, contaminated waste from patients known to have blood-borne infections […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS30(PLC) Picture Burn Rate Average 30-50 kg/hour Feed Capacity Average 60kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 1.0 Kw Oil Consumption (kg/hour) […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Incinerator Model TS10 PLC, Overview This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber […]
Top Openning Door Waste Incinerators Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm Secondary Chamber 600L […]
HICLOVER Top Feeding Door Waste Incinerators ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or 3 sections) Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost […]
HICLOVER Top Feeding Door Waste Incinerators ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or 3 sections) ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. ● Double Combustion Chambers All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. ● Containerized Mobile Incinerators The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck. ● […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. Capacity: Average 300 kgs per hour Model YD–300 Picture Burning Rate Average 300 kgs/hour Feed Capacity Average 500 kgs/feeding Primary Combustion Chamber 2400 Liters Secondary Combustion Chamber 1200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Wet Scrubber System(3 Section Type) Feed […]
Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste On-Site Incineration Solution Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, and medical research facilities. These wastes include both infectious (“red bag”) medical wastes as well as non-infectious, […]
HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration General Waste Incinerator For MSW Mobile Incinerator(Optional) Small-Middle scale, mobile […]
Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste. HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/backup// Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-07-21
Smallest Waste Incinerator for PPE waste face mask glove waste Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney ave 10kgs per hour, 100kgs per day(10hr/day working) Equipment Technical Specifications Model YD-10 Picture Feed Capacity Average 20 kgs per […]
Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original […]
Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw […]
Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil […]
having waste from production process which is having very fine/powder material with moisture of 40%. Will this machine suitable for this application. For power waste, proposal plus wet scrubber system. Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust. Optional 3 section type: […]
HS Code for waste incinerator 84178050 Item Specification Model TS100 PLC Main Product List per 01 set Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator PLC Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 […]
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment(Poultry and dead fish Incinerator Machine) Burn Rate Average 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 970L Internal Dimensions 120x90x90cm Secondary Chamber 480L Smoke Filter Chamber […]
Q: what is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. Items/Model TS30(PLC) Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding […]
Small Waste Incinerator, 10kgs per hour capacity, PLC control Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw […]
Pre-assembled, containerized type Incinerator Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel […]
30kgs rate 60kgs feed oil and gas burner small waste incinerator for Afghanistan Machine Working mode Oil or Gas + Power Voltage 220V Oil consumption (lit/hour) Average 13.3lit/hour/chamber Gas consumption (NG) (m3/hour) 16.0 (m3/hour) (NG) Gas consumption (LPG) (m3/hour) 11.7 (m3/hour) (LPG) Burning rate Average 30kg/hour Feed […]
Waste Incineration HICLOVER Model TS75 Items/Model TS75(PLC) Picture Principle Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 150kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 770L Internal Dimensions 100x81x95cm Secondary Chamber 385L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw […]
medical waste incinerator iraq price HICLOVER TS10 PLC 10kgs per hour Items/Model TS10(PLC) Picture Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage […]
Item Specification Model YD-30C Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy gas burner: 02 sets Oil Tank (if […]
Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto. Door Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – small Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber […]
Model YD-30 Mobile Type Picture Burning Rate Average 30 kgs/hour Feed Capacity Average 60 kgs/feeding Chamber Main Body Stainless Steel Mobile Function With Wheel and Brake Primary Combustion Chamber 280 Liters Secondary Combustion Chamber 150 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V […]
Model A600, crematorium manufacturers Internal Dimensions 130 x 70 x 65cm Suit for Animal Cat – yes Dog – yes Pig – no Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to […]
Mobile Containerized Waste Incinerators pets or human cremation emergency use Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) […]
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. Mix and moisture content not known.Allow for weekly deliveries @ 8 […]
Items/Model TS250(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 210x88x110cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Average […]
General specifications of a 100 kg/hr incinerator No. Description Parameter value model HICLOVER YD100 1 Machine working mode Oil + Power Oil + Power 2 Voltage 220V C 3 phase or 1 phase 220V 1P 3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average […]
Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com/backup/ Email: [email protected]: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-06-27
1. N95 and Disposable Mask Machine 2. 400mm and 1600mm Melt blown Production Line 3. ES Fiber Production Line N95 Face Mask Machine Production Line Melt blown Production Line A.)Optional Capacity: 1600mm Efficiency: 95-97% FOB Term Price: USD per set Price […]
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet […]
N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set N95 Face Mask Machine Production Line on Sale Now! $250,000USD per set l Dimension(L*W*H): 1037*855*1780 l Power Supply 15.3kw mono phase l Net Weight: approx.: 1500kg HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet […]