animal incinerator manufacturer

Spare part list- ignition burner

Item description                                                No of required

Motor     2

Control box  2

Pump couplings   4

Photo cells    Two

Sets ht.

Sets electrodes    4

Oil valve       1

Nozzle   two

 

Parameter Compliance

Type of Waste To treat medical waste, categories A,B,C,D,E

Type of Incinerator Pyrolytic

Nominal Burn rate 50 t0 60 kg/ hr in 3500Kcal/Kg

Loading Manual, Batch Load

De  Ashing Automatic or Manual batch de ashing

The incinerator should avoid the release of black smoke and fine dust throughout the loading

Primary chamber ability 2-3 m³

The insulation   of the combustion chamber should be composed   of refractory bricks, using a higher content of

aluminium and insulates,

The plate of combustion in carborundum avoiding the fixing of glass and slags

Hours of operation /Day >10 hrs

Max Operating Temperatures 1400 °C

Normal Operating Temperatures(Main )  >850 °C

Operating Temperature(Secondary) >1100 °C

It should have digital temperatures regulator( Temperatures regulator in digital watch)

Carbon content of ashes <2%

The setup should be wholly free from visible smoke in addition to offensive odours

Residence time in second room 2 minute minimum

The internal diameter of the Chimney:Ø 400

Height of stack >8m

Burner operation Automatic On/Off

Gas Diesel

Fuel consumption at raed capacity >7kg waste /ltr

Electricity consumption <2kW at rated capacity

Operating Voltage 220 — 240V AC 50Hz

Spare parts Supply for 1 year quoted as alternative

Consumables Supply for 1 year of operation to be mentioned as alternative

Warranty Parts and service support: 1 year minimum article comissioning

Service support <72 hours

Emission standard Compliance BS3316 or equivqlent standard

Procedure filtering system Scruber to be mentioned as alternative

CE Manufacturing Compliance BS EN 746-2-1997

Design Specification Type A,B,C,D,and E of medical waste

Setup and Comissioning  Contained in condition of distribution

Training in preventive and curative maintenance and use of this incinerator Operator training inclusive in offer

capability to treat Plastic Not less than 40% by weight