{"id":757,"date":"2026-03-10T12:21:48","date_gmt":"2026-03-10T12:21:48","guid":{"rendered":"http:\/\/www.hiclover.com\/ad\/?p=757"},"modified":"2026-03-10T12:21:48","modified_gmt":"2026-03-10T12:21:48","slug":"hiclover-incinerator-medical-waste-incinerator-china","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/ad\/hiclover-incinerator-medical-waste-incinerator-china\/","title":{"rendered":"HICLOVER Incinerator medical waste incinerator china"},"content":{"rendered":"<div class='code-block code-block-1' style='margin: 8px 0; clear: both;'>\n<div class=\"klaviyo-form-XrwErA\"><\/div>\n<\/div>\n<figure class=\"post-featured-image\"> <img decoding=\"async\" loading=\"lazy\" width=\"770\" height=\"400\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6172feaa11683.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"medical waste incinerator china\" \/> <\/figure>\n<\/p>\n<p>HICLOVER is top supplier of medical waste incinerator china with hiclover brand and website www.hiclover.com. we design PLC control incinerator for better operation which is key point of the medical waste incinerator.<\/p>\n<table width=\"761\">\n<tbody>\n<tr>\n<td width=\"209\">Items\/Model<\/td>\n<td width=\"107\">TS10(PLC)<\/td>\n<td width=\"110\">TS20(PLC)<\/td>\n<td width=\"112\">TS30(PLC)<\/td>\n<td width=\"111\">TS50(PLC)<\/td>\n<td width=\"112\">TS100(PLC)<\/td>\n<\/tr>\n<tr>\n<td>Burn Rate<\/td>\n<td>10 kg\/hour<\/td>\n<td>20 kg\/hour<\/td>\n<td>30 kg\/hour<\/td>\n<td>50 kg\/hour<\/td>\n<td>100 kg\/hour<\/td>\n<\/tr>\n<tr>\n<td>Feed Capacity<\/td>\n<td>20kg<\/td>\n<td>40kg<\/td>\n<td>60kg<\/td>\n<td>100kg<\/td>\n<td>200 kg<\/td>\n<\/tr>\n<tr>\n<td>Control Mode<\/td>\n<td>PLC<\/td>\n<td>PLC<\/td>\n<td>PLC<\/td>\n<td>PLC<\/td>\n<td>PLC<\/td>\n<\/tr>\n<tr>\n<td>Combustion Chamber<\/td>\n<td>100L<\/td>\n<td>210L<\/td>\n<td>330L<\/td>\n<td>560L<\/td>\n<td>1200L<\/td>\n<\/tr>\n<tr>\n<td>Internal Dimensions<\/td>\n<td>50x50x40cm<\/td>\n<td>65x65x50cm<\/td>\n<td>75x75x60cm<\/td>\n<td>100x80x70cm<\/td>\n<td>120x100x100cm<\/td>\n<\/tr>\n<tr>\n<td>Secondary Chamber<\/td>\n<td>50L<\/td>\n<td>110L<\/td>\n<td>180L<\/td>\n<td>280L<\/td>\n<td>600L<\/td>\n<\/tr>\n<tr>\n<td>Smoke Filter Chamber<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Feed Mode<\/td>\n<td>Manual<\/td>\n<td>Manual<\/td>\n<td>Manual<\/td>\n<td>Manual<\/td>\n<td>Manual<\/td>\n<\/tr>\n<tr>\n<td>Voltage<\/td>\n<td>220V<\/td>\n<td>220V<\/td>\n<td>220V<\/td>\n<td>220V<\/td>\n<td>220V<\/td>\n<\/tr>\n<tr>\n<td>Power<\/td>\n<td>0.5Kw<\/td>\n<td>0.5Kw<\/td>\n<td>0.5Kw<\/td>\n<td>0.7Kw<\/td>\n<td>0.7Kw<\/td>\n<\/tr>\n<tr>\n<td>Oil Consumption (kg\/hour)<\/td>\n<td>5.4&#8211;12.6<\/td>\n<td>7.8&#8211;16.3<\/td>\n<td>10.2&#8211;20<\/td>\n<td>12.1&#8211;24<\/td>\n<td>14&#8211;28<\/td>\n<\/tr>\n<tr>\n<td>Gas Consumption (m3\/hour)<\/td>\n<td>6.2&#8211;11.4<\/td>\n<td>8&#8211;15.7<\/td>\n<td>9.8&#8211;20<\/td>\n<td>9.9&#8211;26.1<\/td>\n<td>10&#8211;32.2<\/td>\n<\/tr>\n<tr>\n<td>Temperature Monitor<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Temperature Protection<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<td>Yes<\/td>\n<\/tr>\n<tr>\n<td>Oil Tank<\/td>\n<td>100L<\/td>\n<td>100L<\/td>\n<td>100L<\/td>\n<td>100L<\/td>\n<td>200L<\/td>\n<\/tr>\n<tr>\n<td>Feed Door<\/td>\n<td>30x30cm<\/td>\n<td>45x40cm<\/td>\n<td>55x50cm<\/td>\n<td>70x55cm<\/td>\n<td>80x60cm<\/td>\n<\/tr>\n<tr>\n<td>Chimney<\/td>\n<td>3Meter<\/td>\n<td>3Meter<\/td>\n<td>5Meter<\/td>\n<td>5Meter<\/td>\n<td>10Meter<\/td>\n<\/tr>\n<tr>\n<td>Chimney Type<\/td>\n<td>Stainless Steel<\/td>\n<td>Stainless Steel<\/td>\n<td>Stainless Steel<\/td>\n<td>Stainless Steel<\/td>\n<td>Stainless Steel<\/td>\n<\/tr>\n<tr>\n<td>1st. Chamber Temperature<\/td>\n<td>800\u2103&#8211;1000\u2103<\/td>\n<td>800\u2103&#8211;1000\u2103<\/td>\n<td>800\u2103&#8211;1000\u2103<\/td>\n<td>800\u2103&#8211;1000\u2103<\/td>\n<td>800\u2103&#8211;1000\u2103<\/td>\n<\/tr>\n<tr>\n<td>2nd. Chamber Temperature<\/td>\n<td>1000\u2103-1200\u2103<\/td>\n<td>1000\u2103-1200\u2103<\/td>\n<td>1000\u2103-1200\u2103<\/td>\n<td>1000\u2103-1200\u2103<\/td>\n<td>1000\u2103-1200\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"209\">Residency Time<\/td>\n<td width=\"107\">2.0 Sec.<\/td>\n<td width=\"110\">2.0 Sec.<\/td>\n<td width=\"112\">2.0 Sec.<\/td>\n<td width=\"111\">2.0 Sec.<\/td>\n<td width=\"112\">2.0 Sec.<\/td>\n<\/tr>\n<tr>\n<td>Gross Weight<\/td>\n<td>1500kg<\/td>\n<td>2200kg<\/td>\n<td>3000kg<\/td>\n<td>4500kg<\/td>\n<td>6000kg<\/td>\n<\/tr>\n<tr>\n<td>External Dimensions<\/td>\n<td>140x90x120cm<\/td>\n<td>160x110x130cm<\/td>\n<td>175x120x140cm<\/td>\n<td>230x130x155cm<\/td>\n<td>260x150x180cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>HICLOVER is top supplier of medical waste incinerator china with hiclover brand and website www.hiclover.com. we design PLC control incinerator for better operation which is key point of the medical waste incinerator. Items\/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg\/hour 20 kg\/hour 30 kg\/hour 50 kg\/hour 100 kg\/hour Feed Capacity 20kg 40kg 60kg [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":758,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[1],"tags":[107,104,54,51,39,109,87,66,147,88,58,38,85,50,89,42,75,17,100,102,15,91,132,19,5,193,28,103,12,18,182,99,21,93,77,111,248,95,45,25,118,105,7,16,64,30,72],"class_list":["post-757","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-incinerators","tag-107","tag-104","tag-a","tag-an","tag-and","tag-at","tag-burn","tag-ca","tag-capacity","tag-chamber","tag-china","tag-clover","tag-co","tag-com","tag-d","tag-de","tag-des","tag-design","tag-di","tag-en","tag-for","tag-gas","tag-hiclover","tag-in","tag-incinerator","tag-incinerator-china","tag-is","tag-kg","tag-medical","tag-medical-waste","tag-medical-waste-incinerator","tag-model","tag-of","tag-oil","tag-on","tag-power","tag-supplier","tag-temperature","tag-the","tag-to","tag-type","tag-us","tag-waste","tag-waste-incinerator","tag-with","tag-www","tag-y"],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/757","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/comments?post=757"}],"version-history":[{"count":1,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/757\/revisions"}],"predecessor-version":[{"id":4161,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/757\/revisions\/4161"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media\/758"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media?parent=757"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/categories?post=757"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/tags?post=757"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}