{"id":611,"date":"2025-10-29T12:20:09","date_gmt":"2025-10-29T12:20:09","guid":{"rendered":"http:\/\/www.hiclover.com\/ad\/?p=611"},"modified":"2025-10-29T12:20:09","modified_gmt":"2025-10-29T12:20:09","slug":"a-complete-destruction-of-waste-from-various-hospital-services-2","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/ad\/a-complete-destruction-of-waste-from-various-hospital-services-2\/","title":{"rendered":"a complete destruction of waste from various hospital services"},"content":{"rendered":"<div class='code-block code-block-1' style='margin: 8px 0; clear: both;'>\n<div class=\"klaviyo-form-XrwErA\"><\/div>\n<\/div>\n<figure class=\"post-featured-image\"> <img decoding=\"async\" loading=\"lazy\" width=\"940\" height=\"368\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6172fd748011f.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" \/> <\/figure>\n<\/p>\n<div>\n<div>\n<div><\/div>\n<div><\/div>\n<div>Medical&nbsp;Waste&nbsp;Incinerator Purpose<\/div>\n<div>For&nbsp;a&nbsp;complete&nbsp;destruction&nbsp;of&nbsp;waste&nbsp;from&nbsp;various&nbsp;hospital&nbsp;services&nbsp;by&nbsp;heat&nbsp;treatment&nbsp;of&nbsp;high&nbsp;temperature&nbsp;in&nbsp;accordance&nbsp;with&nbsp;EU&nbsp;standard&nbsp;on&nbsp;emission&nbsp;requirement.<\/div>\n<div>-Waste&nbsp;from&nbsp;health&nbsp;care&nbsp;activities<\/div>\n<div>-Infections&nbsp;waste,&nbsp;laboratory&nbsp;cultures,&nbsp;waste&nbsp;form&nbsp;operation&nbsp;room&nbsp;isolations&nbsp;material&nbsp;in&nbsp;contact&nbsp;with&nbsp;infected&nbsp;patients,&nbsp;waste&nbsp;potentially&nbsp;being&nbsp;infected&nbsp;by&nbsp;pathogenic&nbsp;agents.&nbsp;<\/div>\n<div>-Pathological&nbsp;waste,&nbsp;human&nbsp;fragments,&nbsp;blood,&nbsp;fetus,&nbsp;all&nbsp;body&nbsp;fluids,&nbsp;human&nbsp;tissues.<\/div>\n<div>-Sculpts,&nbsp;needles,&nbsp;infusion&nbsp;sets,&nbsp;blades,&nbsp;glass<\/div>\n<div>-Pharmaceutical&nbsp;waste.&nbsp;<\/div>\n<div>-Chemical&nbsp;waste&nbsp;laboratory&nbsp;reagents,&nbsp;disinfectants<\/div>\n<div>-Expired&nbsp;drugs.&nbsp;<\/div>\n<div>-Low&nbsp;radiation&nbsp;radioactive&nbsp;element.<\/div>\n<div>Medical&nbsp;waste&nbsp;incinerator:&nbsp;&#8211;&nbsp;Ecological&nbsp;Requirement<\/div>\n<div>&#8211;&nbsp;No&nbsp;odor<\/div>\n<div>-No&nbsp;fume<\/div>\n<div>-Definitive&nbsp;treatment&nbsp;of&nbsp;waste<\/div>\n<div><\/div>\n<div>Medical&nbsp;waste&nbsp;incinerator:&nbsp;&#8211;&nbsp;Manufacturing&nbsp;Standards&nbsp;<\/div>\n<div>-UL,CE,&nbsp;ASME,&nbsp;ISA&nbsp;EURO&nbsp;emission&nbsp;standard&nbsp;<\/div>\n<div><\/div>\n<div>1.Medical&nbsp;waste&nbsp;incinerator&nbsp;<\/div>\n<div><img decoding=\"async\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6172fd75cbc5d.jpg\"><\/div>\n<div>Construction&nbsp;&#8211;&nbsp;CS&nbsp;plate&nbsp;shells,&nbsp;FB&nbsp;reinforcement,&nbsp;cast&nbsp;refractory&nbsp;linings,&nbsp;<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Insulation&nbsp;and&nbsp;14&nbsp;gage&nbsp;aluminum&nbsp;jacket.&nbsp;<\/div>\n<div>Type&nbsp;of&nbsp;fuel&nbsp;&#8211;&nbsp;Oil&nbsp;fired&nbsp;(Diesel)<\/div>\n<div>Burning&nbsp;Capacity&nbsp;&#8211;&nbsp;250kg\/hr&nbsp;and&nbsp;moisture&nbsp;up&nbsp;to&nbsp;80%.<\/div>\n<div>Duration&nbsp;-8-16\/Continuous&nbsp;&nbsp;<\/div>\n<div>Average&nbsp;fuel&nbsp;consumption&nbsp;&#8211;&nbsp;Very&nbsp;little&nbsp;as&nbsp;much&nbsp;as&nbsp;possible<\/div>\n<div>Control&nbsp;Type&nbsp;&#8211;&nbsp;PLC&nbsp;based&nbsp;operation<\/div>\n<div>Operating&nbsp;Temperature&nbsp;&#8211;&nbsp;Primary&nbsp;chamber&nbsp;800oc&nbsp;&plusmn;&nbsp;50<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&#8211;&nbsp;Secondary&nbsp;Chamber&nbsp;1050oc&nbsp;&plusmn;&nbsp;50<\/div>\n<div>Size&nbsp;of&nbsp;incinerator&nbsp;&#8211;&nbsp;Not&nbsp;more&nbsp;than&nbsp;15mx7.20m<\/div>\n<div>Chimney&nbsp;&#8211;&nbsp;&Oslash;630x25meter&nbsp;height&nbsp;&nbsp;and&nbsp;7mm&nbsp;thick&nbsp;CS.<\/div>\n<div>Combustion&nbsp;efficiency-&nbsp;99%<\/div>\n<div>Mode&nbsp;of&nbsp;waste&nbsp;handling-&nbsp;Semi-automatic&nbsp;via&nbsp;ram&nbsp;loader.<\/div>\n<div>Mode&nbsp;of&nbsp;ash&nbsp;handling&nbsp;&#8211;&nbsp;Semi-automatic&nbsp;via&nbsp;grate&nbsp;and&nbsp;ash&nbsp;trolley.<\/div>\n<div>Pollution&nbsp;control&nbsp;equipment-&nbsp;Dry&nbsp;settlement&nbsp;zone<\/div>\n<div>Doors-&nbsp;1-waste&nbsp;charging&nbsp;door&nbsp;in&nbsp;primary&nbsp;chamber<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-clinker&nbsp;door&nbsp;in&nbsp;primary&nbsp;chamber<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-ash&nbsp;trolley&nbsp;access&nbsp;door&nbsp;in&nbsp;primary&nbsp;chamber<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-clean&nbsp;out&nbsp;door&nbsp;in&nbsp;secondary&nbsp;chamber<\/div>\n<div>Burner&nbsp;&#8211;&nbsp;2-&nbsp;ignition&nbsp;burner&nbsp;in&nbsp;primary&nbsp;chamber<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2-&nbsp;after&nbsp;burner&nbsp;in&nbsp;secondary&nbsp;chamber.<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Type-&nbsp;package&nbsp;mono&nbsp;block-fully&nbsp;automatic<\/div>\n<div>Type&nbsp;of&nbsp;burner&nbsp;operation-&nbsp;modulation&nbsp;control<\/div>\n<div>Forced&nbsp;draught&nbsp;fan-&nbsp;1-primary&nbsp;air&nbsp;fan<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-secondary&nbsp;air&nbsp;fan<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<\/div>\n<div>Fuel&nbsp;storage&nbsp;tank&nbsp;&#8211;&nbsp;Capacity-&nbsp;2500liter&nbsp;above&nbsp;ground<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&#8211;&nbsp;Material-6mm&nbsp;thick&nbsp;mild&nbsp;steel<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&#8211;&nbsp;2-diesel&nbsp;pump,&nbsp;gate&nbsp;valve,&nbsp;safety&nbsp;valve,&nbsp;strainer<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Pipe,&nbsp;pressure&nbsp;gage,&nbsp;check&nbsp;valve,&nbsp;control&nbsp;board<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Level&nbsp;indicator.&nbsp;Etc<\/div>\n<div>Refractory\/insulation&nbsp;thickness-&nbsp;not&nbsp;less&nbsp;than&nbsp;225mm<\/div>\n<div>Ram&nbsp;loader&nbsp;capacity-&nbsp;0.75m3<\/div>\n<div>Electrical&nbsp;supply-&nbsp;380v\/3ph\/50&nbsp;Hz<\/div>\n<div>Finish&nbsp;and&nbsp;painting&nbsp;type-&nbsp;powder&nbsp;coated&nbsp;<\/div>\n<div>Audio\/&nbsp;visual&nbsp;alarm&nbsp;system-&nbsp;burner&nbsp;lockout,&nbsp;overload&nbsp;fault&nbsp;<\/div>\n<div>Electrical&nbsp;accessories-&nbsp;primary&nbsp;and&nbsp;secondary&nbsp;chamber&nbsp;temperature&nbsp;<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Controller\/indicator,&nbsp;auto&nbsp;controls,&nbsp;electrical&nbsp;<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Control&nbsp;switches,&nbsp;push&nbsp;buttons,&nbsp;relays,&nbsp;contactors<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Thermocouples,&nbsp;burner&nbsp;sequence&nbsp;controllers,<\/div>\n<div>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Timers,&nbsp;emergency&nbsp;stop&nbsp;and&nbsp;alarms.<\/div>\n<\/p>\n<\/div>\n<\/div>\n<div id='gallery-2' class='gallery galleryid-394 gallery-columns-3 gallery-size-thumbnail'>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'> <a href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/33-2'><img decoding=\"async\" loading=\"lazy\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6172fd7656edc.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a> <\/div>\n<\/figure>\n<figure class='gallery-item'>\n<div class='gallery-icon landscape'> <a href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/hiclover-incinerators'><img decoding=\"async\" loading=\"lazy\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6172fd76d5551.jpg\" class=\"attachment-thumbnail size-thumbnail\" alt=\"\" \/><\/a> <\/div>\n<\/figure>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Medical&nbsp;Waste&nbsp;Incinerator Purpose For&nbsp;a&nbsp;complete&nbsp;destruction&nbsp;of&nbsp;waste&nbsp;from&nbsp;various&nbsp;hospital&nbsp;services&nbsp;by&nbsp;heat&nbsp;treatment&nbsp;of&nbsp;high&nbsp;temperature&nbsp;in&nbsp;accordance&nbsp;with&nbsp;EU&nbsp;standard&nbsp;on&nbsp;emission&nbsp;requirement. -Waste&nbsp;from&nbsp;health&nbsp;care&nbsp;activities -Infections&nbsp;waste,&nbsp;laboratory&nbsp;cultures,&nbsp;waste&nbsp;form&nbsp;operation&nbsp;room&nbsp;isolations&nbsp;material&nbsp;in&nbsp;contact&nbsp;with&nbsp;infected&nbsp;patients,&nbsp;waste&nbsp;potentially&nbsp;being&nbsp;infected&nbsp;by&nbsp;pathogenic&nbsp;agents.&nbsp; -Pathological&nbsp;waste,&nbsp;human&nbsp;fragments,&nbsp;blood,&nbsp;fetus,&nbsp;all&nbsp;body&nbsp;fluids,&nbsp;human&nbsp;tissues. -Sculpts,&nbsp;needles,&nbsp;infusion&nbsp;sets,&nbsp;blades,&nbsp;glass -Pharmaceutical&nbsp;waste.&nbsp; -Chemical&nbsp;waste&nbsp;laboratory&nbsp;reagents,&nbsp;disinfectants -Expired&nbsp;drugs.&nbsp; -Low&nbsp;radiation&nbsp;radioactive&nbsp;element. Medical&nbsp;waste&nbsp;incinerator:&nbsp;&#8211;&nbsp;Ecological&nbsp;Requirement &#8211;&nbsp;No&nbsp;odor -No&nbsp;fume -Definitive&nbsp;treatment&nbsp;of&nbsp;waste Medical&nbsp;waste&nbsp;incinerator:&nbsp;&#8211;&nbsp;Manufacturing&nbsp;Standards&nbsp; -UL,CE,&nbsp;ASME,&nbsp;ISA&nbsp;EURO&nbsp;emission&nbsp;standard&nbsp; 1.Medical&nbsp;waste&nbsp;incinerator&nbsp; Construction&nbsp;&#8211;&nbsp;CS&nbsp;plate&nbsp;shells,&nbsp;FB&nbsp;reinforcement,&nbsp;cast&nbsp;refractory&nbsp;linings,&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Insulation&nbsp;and&nbsp;14&nbsp;gage&nbsp;aluminum&nbsp;jacket.&nbsp; Type&nbsp;of&nbsp;fuel&nbsp;&#8211;&nbsp;Oil&nbsp;fired&nbsp;(Diesel) Burning&nbsp;Capacity&nbsp;&#8211;&nbsp;250kg\/hr&nbsp;and&nbsp;moisture&nbsp;up&nbsp;to&nbsp;80%. Duration&nbsp;-8-16\/Continuous&nbsp;&nbsp; Average&nbsp;fuel&nbsp;consumption&nbsp;&#8211;&nbsp;Very&nbsp;little&nbsp;as&nbsp;much&nbsp;as&nbsp;possible Control&nbsp;Type&nbsp;&#8211;&nbsp;PLC&nbsp;based&nbsp;operation Operating&nbsp;Temperature&nbsp;&#8211;&nbsp;Primary&nbsp;chamber&nbsp;800oc&nbsp;&plusmn;&nbsp;50 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&#8211;&nbsp;Secondary&nbsp;Chamber&nbsp;1050oc&nbsp;&plusmn;&nbsp;50 Size&nbsp;of&nbsp;incinerator&nbsp;&#8211;&nbsp;Not&nbsp;more&nbsp;than&nbsp;15mx7.20m Chimney&nbsp;&#8211;&nbsp;&Oslash;630x25meter&nbsp;height&nbsp;&nbsp;and&nbsp;7mm&nbsp;thick&nbsp;CS. Combustion&nbsp;efficiency-&nbsp;99% Mode&nbsp;of&nbsp;waste&nbsp;handling-&nbsp;Semi-automatic&nbsp;via&nbsp;ram&nbsp;loader. Mode&nbsp;of&nbsp;ash&nbsp;handling&nbsp;&#8211;&nbsp;Semi-automatic&nbsp;via&nbsp;grate&nbsp;and&nbsp;ash&nbsp;trolley. Pollution&nbsp;control&nbsp;equipment-&nbsp;Dry&nbsp;settlement&nbsp;zone Doors-&nbsp;1-waste&nbsp;charging&nbsp;door&nbsp;in&nbsp;primary&nbsp;chamber &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-clinker&nbsp;door&nbsp;in&nbsp;primary&nbsp;chamber &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-ash&nbsp;trolley&nbsp;access&nbsp;door&nbsp;in&nbsp;primary&nbsp;chamber &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-clean&nbsp;out&nbsp;door&nbsp;in&nbsp;secondary&nbsp;chamber Burner&nbsp;&#8211;&nbsp;2-&nbsp;ignition&nbsp;burner&nbsp;in&nbsp;primary&nbsp;chamber &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;2-&nbsp;after&nbsp;burner&nbsp;in&nbsp;secondary&nbsp;chamber. &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Type-&nbsp;package&nbsp;mono&nbsp;block-fully&nbsp;automatic Type&nbsp;of&nbsp;burner&nbsp;operation-&nbsp;modulation&nbsp;control Forced&nbsp;draught&nbsp;fan-&nbsp;1-primary&nbsp;air&nbsp;fan &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;1-secondary&nbsp;air&nbsp;fan &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Fuel&nbsp;storage&nbsp;tank&nbsp;&#8211;&nbsp;Capacity-&nbsp;2500liter&nbsp;above&nbsp;ground &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&#8211;&nbsp;Material-6mm&nbsp;thick&nbsp;mild&nbsp;steel &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&#8211;&nbsp;2-diesel&nbsp;pump,&nbsp;gate&nbsp;valve,&nbsp;safety&nbsp;valve,&nbsp;strainer &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Pipe,&nbsp;pressure&nbsp;gage,&nbsp;check&nbsp;valve,&nbsp;control&nbsp;board &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Level&nbsp;indicator.&nbsp;Etc Refractory\/insulation&nbsp;thickness-&nbsp;not&nbsp;less&nbsp;than&nbsp;225mm Ram&nbsp;loader&nbsp;capacity-&nbsp;0.75m3 Electrical&nbsp;supply-&nbsp;380v\/3ph\/50&nbsp;Hz Finish&nbsp;and&nbsp;painting&nbsp;type-&nbsp;powder&nbsp;coated&nbsp; Audio\/&nbsp;visual&nbsp;alarm&nbsp;system-&nbsp;burner&nbsp;lockout,&nbsp;overload&nbsp;fault&nbsp; Electrical&nbsp;accessories-&nbsp;primary&nbsp;and&nbsp;secondary&nbsp;chamber&nbsp;temperature&nbsp; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":612,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[1],"tags":[107,104,54,137,51,39,98,79,109,87,136,151,86,66,147,88,149,38,85,50,90,89,42,75,120,100,124,145,102,24,152,15,76,150,132,80,26,110,19,5,6,28,103,154,12,21,93,77,153,144,117,123,148,92,95,45,25,67,118,82,105,7,64,30,72],"class_list":["post-611","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-incinerators","tag-107","tag-104","tag-a","tag-air","tag-an","tag-and","tag-are","tag-ash","tag-at","tag-burn","tag-burner","tag-burning","tag-by","tag-ca","tag-capacity","tag-chamber","tag-chemical","tag-clover","tag-co","tag-com","tag-construction","tag-d","tag-de","tag-des","tag-destruction","tag-di","tag-diesel","tag-electric","tag-en","tag-equipment","tag-fired","tag-for","tag-from","tag-health","tag-hiclover","tag-high","tag-hospital","tag-human","tag-in","tag-incinerator","tag-incinerators","tag-is","tag-kg","tag-manufacturing","tag-medical","tag-of","tag-oil","tag-on","tag-pharmaceutical","tag-pollution","tag-ru","tag-sa","tag-services","tag-system","tag-temperature","tag-the","tag-to","tag-treatment","tag-type","tag-un","tag-us","tag-waste","tag-with","tag-www","tag-y"],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/611","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/comments?post=611"}],"version-history":[{"count":1,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/611\/revisions"}],"predecessor-version":[{"id":3322,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/611\/revisions\/3322"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media\/612"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media?parent=611"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/categories?post=611"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/tags?post=611"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}