{"id":1128,"date":"2026-03-09T12:27:52","date_gmt":"2026-03-09T12:27:52","guid":{"rendered":"http:\/\/www.hiclover.com\/ad\/?p=1128"},"modified":"2026-03-09T12:27:53","modified_gmt":"2026-03-09T12:27:53","slug":"controlled-air-medical-waste-incinerator-designed-for-incineration-of-bio-medical-waste","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/ad\/controlled-air-medical-waste-incinerator-designed-for-incineration-of-bio-medical-waste\/","title":{"rendered":"Controlled air medical waste incinerator designed for incineration of bio-medical waste"},"content":{"rendered":"<div class='code-block code-block-1' style='margin: 8px 0; clear: both;'>\n<div class=\"klaviyo-form-XrwErA\"><\/div>\n<\/div>\n<figure class=\"post-featured-image\"><img decoding=\"async\" loading=\"lazy\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6173018a021f2.jpg\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" alt=\"\" width=\"800\" height=\"600\" \/><\/figure>\n<div class=\"entry-content clearfix\">\n<div>Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )<\/p>\n<div><span style=\"color: #000000; background-color: rgba(0, 0, 0, 0);\"><span style=\"color: #000000; background-color: rgba(0, 0, 0, 0);\">Operational\u00a0Specs Physical\u00a0Specs<br \/>\nCombustion\u00a0Chamber\u00a0Volume\u00a0(m3) 8.80m3<br \/>\nBurn\u00a0Rate* up\u00a0to\u00a01,500kg\u00a0per\u00a0hour<br \/>\nAverage\u00a0Fuel\u00a0Consumption 65\u00a0kg\u00a0per\u00a0hour\u00a0or\u00a0more\u00a0(7\u00a0diesel\u00a0burners)<br \/>\nOperational\u00a0Temperature 850\u00a0\u2013\u00a01320\u00b0C<br \/>\nGas\u00a0Retention\u00a0in\u00a0Secondary\u00a0Chamber Large\u00a0secondary\u00a0chamber<br \/>\nTemperature\u00a0Monitoring Yes<br \/>\nAverage\u00a0ash\u00a0residue\u00a0(%) 3%<br \/>\nThermostatic\u00a0Device Yes<br \/>\n1000l\u00a0diesel\u00a0flue\u00a0tank<br \/>\nVenture\u00a0gas\u00a0scrubber<br \/>\nHydraulic\u00a0Ram\u00a0Feeding\u00a0System<br \/>\nDiesel\u00a0Powered\u00a0Large\u00a0Incinerator<br \/>\nMinimum\u00a0Specification\u00a0Required<\/span><\/span><\/p>\n<p>Standards<br \/>\n1)\u00a0Bidder\u00a0or\u00a0Manufacturer\u00a0ISO\u00a09001\u00a0Certified<br \/>\n2)\u00a0Respecting\u00a0international\u00a0emission\u00a0standards<br \/>\nElectrical\u00a0characteristics<br \/>\n3)\u00a0A\u00a0230V,\u00a060Hz\u00a0single-phase\u00a0electrical\u00a0source.<br \/>\n4)\u00a0Protections\u00a0against\u00a0over-voltage\u00a0and\u00a0over-current\u00a0line\u00a0conditions.<br \/>\n5)\u00a0Compliance\u00a0with\u00a0applicable\u00a0Ghanaian\u00a0standards\u00a0and\u00a0regulations.<br \/>\nOperational\u00a0characteristics<br \/>\n6)\u00a0Two-stage\u00a0incineration\u00a0with\u00a0dual\u00a0chamber\u00a0combustion<br \/>\n7)\u00a0Burn\u00a0rate:\u00a015\u00a0\u2013\u00a020\u00a0Kg\/h<br \/>\n8)\u00a0Capacity:\u00a0not\u00a0less\u00a0than\u00a0130\u00a0L<br \/>\n9)\u00a0Concentrations\u00a0of\u00a0most\u00a0pollutants\u00a0in\u00a0stack\u00a0gases\u00a0below\u00a0detection\u00a0limits<br \/>\n10)\u00a0Diesel\u00a0fuel<br \/>\n11)\u00a0Electronic\u00a0system\u00a0control<br \/>\n12)\u00a0Easy\u00a0to\u00a0operate\u00a0and\u00a0minimal\u00a0training<br \/>\n13)\u00a0Any\u00a0accessory\u00a0or\u00a0dedicated\u00a0device\u00a0necessary\u00a0to\u00a0the\u00a0proper\u00a0functioning\u00a0and\u00a0utilization\u00a0of\u00a0the\u00a0equipment\u00a0included<\/p>\n<p>PLEASE\u00a0REFER\u00a0TO\u00a0BROCHURES\u00a0ATTACHED\u00a0FOR\u00a0DETAILED\u00a0SPECIFICATION<\/p>\n<\/div>\n<\/div>\n<\/div>\n<div class='yarpp yarpp-related yarpp-related-website yarpp-template-thumbnails'>\n<h3>Related posts:<\/h3>\n<div class=\"yarpp-thumbnails-horizontal\">\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/diesel-fuel-incinerator-1' title='Diesel Fuel Incinerator'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6173018a25ff3.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Diesel Fuel Incinerator<\/span><\/a><br \/>\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/medical-waste-incinerator-14-1' title='Medical Waste Incinerator'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6173018a4f442.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Medical Waste Incinerator<\/span><\/a><br \/>\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/medical-waste-incinerator-15-1' title='Medical Waste Incinerator'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6173018a734a5.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Medical Waste Incinerator<\/span><\/a><br \/>\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/catalogue-of-incenarator-for-pharmaceuticals-waste-1' title='Catalogue of Incenarator for Pharmaceuticals Waste'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_6173018a9ff28.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Catalogue of Incenarator for Pharmaceuticals Waste<\/span><\/a>\n<\/div>\n<\/div>\n<div class='code-block code-block-5' style='margin: 8px 0; clear: both;'>\n<div class=\"klaviyo-form-SV65JQ\"><\/div>\n<\/div>\n<div>Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )<\/p>\n<div><span style=\"color: #000000; background-color: rgba(0, 0, 0, 0);\"><span style=\"color: #000000; background-color: rgba(0, 0, 0, 0);\">Operational\u00a0Specs Physical\u00a0Specs<br \/>\nCombustion\u00a0Chamber\u00a0Volume\u00a0(m3) 8.80m3<br \/>\nBurn\u00a0Rate* up\u00a0to\u00a01,500kg\u00a0per\u00a0hour<br \/>\nAverage\u00a0Fuel\u00a0Consumption 65\u00a0kg\u00a0per\u00a0hour\u00a0or\u00a0more\u00a0(7\u00a0diesel\u00a0burners)<br \/>\nOperational\u00a0Temperature 850\u00a0\u2013\u00a01320\u00b0C<br \/>\nGas\u00a0Retention\u00a0in\u00a0Secondary\u00a0Chamber Large\u00a0secondary\u00a0chamber<br \/>\nTemperature\u00a0Monitoring Yes<br \/>\nAverage\u00a0ash\u00a0residue\u00a0(%) 3%<br \/>\nThermostatic\u00a0Device Yes<br \/>\n1000l\u00a0diesel\u00a0flue\u00a0tank<br \/>\nVenture\u00a0gas\u00a0scrubber<br \/>\nHydraulic\u00a0Ram\u00a0Feeding\u00a0System<br \/>\nDiesel\u00a0Powered\u00a0Large\u00a0Incinerator<br \/>\nMinimum\u00a0Specification\u00a0Required<\/span><\/span><\/p>\n<p>Standards<br \/>\n1)\u00a0Bidder\u00a0or\u00a0Manufacturer\u00a0ISO\u00a09001\u00a0Certified<br \/>\n2)\u00a0Respecting\u00a0international\u00a0emission\u00a0standards<br \/>\nElectrical\u00a0characteristics<br \/>\n3)\u00a0A\u00a0230V,\u00a060Hz\u00a0single-phase\u00a0electrical\u00a0source.<br \/>\n4)\u00a0Protections\u00a0against\u00a0over-voltage\u00a0and\u00a0over-current\u00a0line\u00a0conditions.<br \/>\n5)\u00a0Compliance\u00a0with\u00a0applicable\u00a0Ghanaian\u00a0standards\u00a0and\u00a0regulations.<br \/>\nOperational\u00a0characteristics<br \/>\n6)\u00a0Two-stage\u00a0incineration\u00a0with\u00a0dual\u00a0chamber\u00a0combustion<br \/>\n7)\u00a0Burn\u00a0rate:\u00a015\u00a0\u2013\u00a020\u00a0Kg\/h<br \/>\n8)\u00a0Capacity:\u00a0not\u00a0less\u00a0than\u00a0130\u00a0L<br \/>\n9)\u00a0Concentrations\u00a0of\u00a0most\u00a0pollutants\u00a0in\u00a0stack\u00a0gases\u00a0below\u00a0detection\u00a0limits<br \/>\n10)\u00a0Diesel\u00a0fuel<br \/>\n11)\u00a0Electronic\u00a0system\u00a0control<br \/>\n12)\u00a0Easy\u00a0to\u00a0operate\u00a0and\u00a0minimal\u00a0training<br \/>\n13)\u00a0Any\u00a0accessory\u00a0or\u00a0dedicated\u00a0device\u00a0necessary\u00a0to\u00a0the\u00a0proper\u00a0functioning\u00a0and\u00a0utilization\u00a0of\u00a0the\u00a0equipment\u00a0included<\/p>\n<p>PLEASE\u00a0REFER\u00a0TO\u00a0BROCHURES\u00a0ATTACHED\u00a0FOR\u00a0DETAILED\u00a0SPECIFICATION<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. ) Operational\u00a0Specs Physical\u00a0Specs Combustion\u00a0Chamber\u00a0Volume\u00a0(m3) 8.80m3 Burn\u00a0Rate* up\u00a0to\u00a01,500kg\u00a0per\u00a0hour Average\u00a0Fuel\u00a0Consumption [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1129,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[1],"tags":[107,104,54,137,51,39,79,109,87,136,66,147,88,38,85,50,89,42,75,17,100,124,145,102,24,15,91,271,35,43,132,19,269,8,5,169,116,28,103,121,68,12,18,182,191,138,21,77,153,111,176,117,123,92,95,45,25,82,105,7,16,64,30,72],"class_list":["post-1128","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-incinerators","tag-107","tag-104","tag-a","tag-air","tag-an","tag-and","tag-ash","tag-at","tag-burn","tag-burner","tag-ca","tag-capacity","tag-chamber","tag-clover","tag-co","tag-com","tag-d","tag-de","tag-des","tag-design","tag-di","tag-diesel","tag-electric","tag-en","tag-equipment","tag-for","tag-gas","tag-ghana","tag-hazardous","tag-hazardous-waste","tag-hiclover","tag-in","tag-incenarator","tag-incineration","tag-incinerator","tag-incinerator-design","tag-infectious","tag-is","tag-kg","tag-large","tag-manufacturer","tag-medical","tag-medical-waste","tag-medical-waste-incinerator","tag-medical-waste-incinerator-design","tag-mini","tag-of","tag-on","tag-pharmaceutical","tag-power","tag-process","tag-ru","tag-sa","tag-system","tag-temperature","tag-the","tag-to","tag-un","tag-us","tag-waste","tag-waste-incinerator","tag-with","tag-www","tag-y"],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/1128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/comments?post=1128"}],"version-history":[{"count":1,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/1128\/revisions"}],"predecessor-version":[{"id":3237,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/1128\/revisions\/3237"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media\/1129"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media?parent=1128"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/categories?post=1128"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/tags?post=1128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}