{"id":1117,"date":"2026-01-26T12:21:08","date_gmt":"2026-01-26T12:21:08","guid":{"rendered":"http:\/\/www.hiclover.com\/ad\/?p=1117"},"modified":"2026-01-26T12:21:10","modified_gmt":"2026-01-26T12:21:10","slug":"medical-incinerator-specification-2","status":"publish","type":"post","link":"https:\/\/www.hiclover.com\/ad\/medical-incinerator-specification-2\/","title":{"rendered":"Medical Incinerator Specification"},"content":{"rendered":"<div class='code-block code-block-1' style='margin: 8px 0; clear: both;'>\n<div class=\"klaviyo-form-XrwErA\"><\/div>\n<\/div>\n<figure class=\"post-featured-image\"> <img decoding=\"async\" loading=\"lazy\" width=\"960\" height=\"720\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_61730165af5ac.jpg\" class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" alt=\"\" sizes=\"auto, (max-width: 960px) 100vw, 960px\" \/> <\/figure>\n<\/p>\n<div>\n<div><span><\/span><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\">Capacity<span style=\"white-space: pre;\"> <\/span>Not&nbsp;less&nbsp;than&nbsp;500Kg\/hr.<br \/>Operation<span style=\"white-space: pre;\"> <\/span>24hr-7days\/week&nbsp;continuous&nbsp;operation.<br \/>Combustion&nbsp;chamber<span style=\"white-space: pre;\"> <\/span>2&nbsp;combustion&nbsp;chamber.<br \/>Temp.<span style=\"white-space: pre;\"> <\/span>First&nbsp;combustion&nbsp;chamber&nbsp;800-1000&nbsp;C.<br \/><span style=\"white-space: pre;\"> <\/span>Secandry&nbsp;combustion&nbsp;chamber&nbsp;1000-1200&nbsp;C,&nbsp;with&nbsp;the&nbsp;possibility&nbsp;to&nbsp;be&nbsp;upgraded&nbsp;to&nbsp;1400&nbsp;C.<br \/>Combustion&nbsp;Efficiency<span style=\"white-space: pre;\"> <\/span>99.99%<br \/>Retention&nbsp;time<span style=\"white-space: pre;\"> <\/span>Of&nbsp;the&nbsp;flow&nbsp;gases&nbsp;not&nbsp;less&nbsp;than&nbsp;2&nbsp;Sec&nbsp;in&nbsp;the&nbsp;hot&nbsp;portion.<br \/>Excess&nbsp;Oxygen&nbsp;concentration<span style=\"white-space: pre;\"> <\/span>Of&nbsp;primary&nbsp;combustion&nbsp;chamber&nbsp;3-6%&nbsp;max.<\/span><\/div>\n<div><img decoding=\"async\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_61730166742bf.jpg\" border=\"0\"><span style=\"color: rgb(0, 0, 0); background-color: rgba(0, 0, 0, 0);\"><br \/>Refractory<span style=\"white-space: pre;\"> <\/span>The&nbsp;chambers&nbsp;should&nbsp;be&nbsp;lined&nbsp;with&nbsp;high&nbsp;thermal&nbsp;insulating&nbsp;refractory&nbsp;bricks&nbsp;with&nbsp;suitable&nbsp;thickness&nbsp;and&nbsp;with&nbsp;highly&nbsp;temp.&nbsp;<br \/>resistance.&nbsp;Not&nbsp;less&nbsp;than&nbsp;1400&nbsp;C&nbsp;for&nbsp;the&nbsp;first&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;not&nbsp;less&nbsp;than&nbsp;1600&nbsp;C&nbsp;for&nbsp;the&nbsp;secandry&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;at&nbsp;the&nbsp;<br \/>same&nbsp;time&nbsp;prevent&nbsp;the&nbsp;Temp.&nbsp;of&nbsp;the&nbsp;outside&nbsp;body&nbsp;of&nbsp;the&nbsp;chamber&nbsp;not&nbsp;higher&nbsp;than&nbsp;70&nbsp;C.<br \/>Doors<span style=\"white-space: pre;\"> <\/span>Should&nbsp;be&nbsp;lined&nbsp;with&nbsp;the&nbsp;same&nbsp;bricks,&nbsp;and&nbsp;the&nbsp;edges&nbsp;lined&nbsp;with&nbsp;special&nbsp;suitable&nbsp;insulating&nbsp;material&nbsp;to&nbsp;prevent&nbsp;any&nbsp;gas&nbsp;escaping,&nbsp;and&nbsp;<br \/>the&nbsp;doors&nbsp;should&nbsp;be&nbsp;kept&nbsp;under&nbsp;negative&nbsp;pressure&nbsp;during&nbsp;the&nbsp;operation.<br \/>Air&nbsp;Emission&nbsp;Control&nbsp;System<span style=\"white-space: pre;\"> <\/span>With&nbsp;high&nbsp;destruction&nbsp;and&nbsp;removal&nbsp;efficiency&nbsp;(DRE).&nbsp;Not&nbsp;less&nbsp;than&nbsp;99.9999&nbsp;as&nbsp;per&nbsp;KEPA.<br \/>Wet&nbsp;System<span style=\"white-space: pre;\"> <\/span>If&nbsp;the&nbsp;system&nbsp;equiped&nbsp;with&nbsp;a&nbsp;CEMS&nbsp;washing&nbsp;the&nbsp;flow&nbsp;gas&nbsp;with&nbsp;water,&nbsp;then&nbsp;it&nbsp;should&nbsp;be&nbsp;manufactured&nbsp;from&nbsp;suitable&nbsp;anti&nbsp;<br \/>corrossion&nbsp;materials,&nbsp;and&nbsp;equiped&nbsp;with&nbsp;pH&nbsp;meter&nbsp;to&nbsp;measure&nbsp;and&nbsp;neutralize&nbsp;the&nbsp;water.&nbsp;It&nbsp;should&nbsp;be&nbsp;able&nbsp;to&nbsp;use&nbsp;the&nbsp;water&nbsp;in&nbsp;closed&nbsp;recycled&nbsp;<br \/>circuit&nbsp;many&nbsp;times&nbsp;before&nbsp;treating\/&nbsp;discharging&nbsp;into&nbsp;the&nbsp;sewage&nbsp;system&nbsp;in&nbsp;compliance&nbsp;with&nbsp;KEPARS.<br \/>Chemical&nbsp;dosing<span style=\"white-space: pre;\"> <\/span>It&nbsp;should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;suitable&nbsp;autochemical&nbsp;dosing&nbsp;system&nbsp;to&nbsp;control&nbsp;the&nbsp;pH&nbsp;for&nbsp;the&nbsp;water&nbsp;of&nbsp;the&nbsp;wet&nbsp;scrubber&nbsp;system&nbsp;<br \/>including&nbsp;sensors.<br \/>Chimney<span style=\"white-space: pre;\"> <\/span>It&nbsp;should&nbsp;be&nbsp;suitable&nbsp;with&nbsp;the&nbsp;capacity&nbsp;and&nbsp;the&nbsp;technical&nbsp;specifications,&nbsp;with&nbsp;height&nbsp;not&nbsp;less&nbsp;than&nbsp;12m&nbsp;from&nbsp;ground&nbsp;level.&nbsp;With&nbsp;easy&nbsp;<br \/>opennable&nbsp;sampling&nbsp;point&nbsp;equal&nbsp;about&nbsp;3&nbsp;inch,&nbsp;and&nbsp;the&nbsp;optimum&nbsp;sampling&nbsp;locations&nbsp;is&nbsp;at&nbsp;least&nbsp;8D&nbsp;downstream&nbsp;direction&nbsp;and&nbsp;2D&nbsp;upstream&nbsp;from&nbsp;any&nbsp;<br \/>flow&nbsp;disturbancies.<br \/>Sampling&nbsp;point<span style=\"white-space: pre;\"> <\/span>Should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;a&nbsp;platform&nbsp;located&nbsp;down&nbsp;the&nbsp;sampling&nbsp;point&nbsp;by&nbsp;a&nbsp;distance&nbsp;not&nbsp;less&nbsp;than&nbsp;1&nbsp;m,&nbsp;and&nbsp;equiped&nbsp;with&nbsp;suitable&nbsp;<br \/>stairs&nbsp;from&nbsp;ground&nbsp;to&nbsp;the&nbsp;port&nbsp;with&nbsp;comfortable&nbsp;slope.<br \/>Ash&nbsp;Removal<span style=\"white-space: pre;\"> <\/span>It&nbsp;should&nbsp;be&nbsp;auto&nbsp;ash&nbsp;removal&nbsp;system.<br \/>Fuel<span style=\"white-space: pre;\"> <\/span>It&nbsp;should&nbsp;be&nbsp;dual&nbsp;system,&nbsp;such&nbsp;as&nbsp;diesel&nbsp;and&nbsp;natural&nbsp;gas.<br \/>Feeding&nbsp;System<span style=\"white-space: pre;\"> <\/span>Should&nbsp;be&nbsp;auto&nbsp;feeding&nbsp;system&nbsp;into&nbsp;primary&nbsp;chamber.<br \/>Control&nbsp;Room<span style=\"white-space: pre;\"> <\/span>Should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;a&nbsp;control&nbsp;panel&nbsp;shows&nbsp;Temp.&nbsp;of&nbsp;the&nbsp;combustion&nbsp;burners,&nbsp;gas&nbsp;monitoring,&nbsp;digital&nbsp;Temp.&nbsp;indecation&nbsp;for&nbsp;the&nbsp;<br \/>primary\/secondary&nbsp;chambers,&nbsp;digital&nbsp;Temp.&nbsp;indication&nbsp;for&nbsp;the&nbsp;gases\u2026etc.&nbsp;it&nbsp;should&nbsp;be&nbsp;also&nbsp;Auto&nbsp;operation,&nbsp;burnures&nbsp;on\/off&nbsp;auto&nbsp;lamps&nbsp;switch,&nbsp;<br \/>auto&nbsp;start\/stop&nbsp;for&nbsp;air&nbsp;emission&nbsp;control&nbsp;system,&nbsp;auto&nbsp;gas&nbsp;continuous&nbsp;monitoring&nbsp;system&nbsp;reading&nbsp;and&nbsp;print&nbsp;out&nbsp;of&nbsp;gas&nbsp;emission&nbsp;parameters&#8230;etc.<br \/>Cooling&nbsp;System<span style=\"white-space: pre;\"> <\/span>The&nbsp;primary&nbsp;chamber&nbsp;should&nbsp;be&nbsp;provided&nbsp;with&nbsp;auto&nbsp;cooling&nbsp;systemthrough&nbsp;nozzles&nbsp;to&nbsp;permit&nbsp;direct&nbsp;cooling&nbsp;if&nbsp;the&nbsp;Temp.&nbsp;will&nbsp;be&nbsp;<br \/>heigher&nbsp;than&nbsp;1100&nbsp;C.<br \/>Inter-lock&nbsp;system<span style=\"white-space: pre;\"> <\/span>The&nbsp;incinerator&nbsp;should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;inter-lock&nbsp;system&nbsp;to&nbsp;prevent&nbsp;feeding&nbsp;the&nbsp;waste&nbsp;to&nbsp;the&nbsp;primary&nbsp;chamber&nbsp;if&nbsp;the&nbsp;<br \/>combustion&nbsp;Temp.&nbsp;less&nbsp;than&nbsp;500&nbsp;C.<br \/>Flue&nbsp;treatment&nbsp;and&nbsp;cleaning<span style=\"white-space: pre;\"> <\/span>To&nbsp;consist&nbsp;a&nbsp;combined&nbsp;system&nbsp;(wet\/dry),&nbsp;using&nbsp;water,&nbsp;lime,&nbsp;active&nbsp;carbon&nbsp;and&nbsp;ceramic&nbsp;filters.<br \/>Quenching&nbsp;system\/Heat&nbsp;exchanger<span style=\"white-space: pre;\"> <\/span>Should&nbsp;be&nbsp;made&nbsp;and&nbsp;manufactured&nbsp;from&nbsp;anti&nbsp;corrosion&nbsp;and&nbsp;acid&nbsp;attack&nbsp;materials&nbsp;such&nbsp;as&nbsp;stainless&nbsp;steel&nbsp;316&nbsp;or&nbsp;<br \/>equivalent.<br \/>Noise&nbsp;Level<span style=\"white-space: pre;\"> <\/span>Not&nbsp;more&nbsp;than&nbsp;85&nbsp;dBA&nbsp;during&nbsp;normal&nbsp;operation.<br \/>Inaddition<span style=\"white-space: pre;\"> <\/span>The&nbsp;desigh&nbsp;should&nbsp;insure&nbsp;that&nbsp;responsive&nbsp;fail-safe&nbsp;control&nbsp;systems&nbsp;are&nbsp;used.<br \/><span style=\"white-space: pre;\"> <\/span>The&nbsp;incinerator&nbsp;should&nbsp;be&nbsp;installed&nbsp;inside&nbsp;closed&nbsp;suitable&nbsp;building&nbsp;with&nbsp;good&nbsp;aeration&nbsp;and&nbsp;ventilation&nbsp;system.&nbsp;The&nbsp;building&nbsp;has&nbsp;<br \/>facilities&nbsp;for&nbsp;off-loading&nbsp;of&nbsp;wastes&nbsp;from&nbsp;transport&nbsp;vehicles.&nbsp;Auto&nbsp;cleaning&nbsp;system&nbsp;for&nbsp;trucks&nbsp;and&nbsp;waste&nbsp;containers,&nbsp;and&nbsp;cool&nbsp;storage&nbsp;<br \/>area&#8230;etc.<br \/><span style=\"white-space: pre;\"> <\/span>The&nbsp;quotation&nbsp;should&nbsp;included&nbsp;list&nbsp;of&nbsp;original&nbsp;spare&nbsp;parts&nbsp;for&nbsp;7&nbsp;years.<br \/><span style=\"white-space: pre;\"> <\/span>The&nbsp;quotation&nbsp;should&nbsp;include&nbsp;supervising,&nbsp;starting&nbsp;up&nbsp;and&nbsp;training&nbsp;of&nbsp;the&nbsp;operators&nbsp;and&nbsp;ministry&nbsp;of&nbsp;health&nbsp;engineers&nbsp;inside\/outside&nbsp;<br \/>Kuwait.<br \/><span style=\"white-space: pre;\"> <\/span>Detailed&nbsp;drawings,&nbsp;catalogs&nbsp;should&nbsp;be&nbsp;included.<br \/><\/span><\/div>\n<div class='yarpp yarpp-related yarpp-related-website yarpp-template-thumbnails'>\n<h3>Related posts:<\/h3>\n<div class=\"yarpp-thumbnails-horizontal\">\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/leading-waste-incinerator-1' title='Leading Waste Incinerator'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_617301669d023.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Leading Waste Incinerator<\/span><\/a><br \/>\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/smallest-waste-incineration-into-energy-system' title='Smallest Waste Incineration Into Energy System'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_61730166c5061.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Smallest Waste Incineration Into Energy System<\/span><\/a><br \/>\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/incinerator-16' title='Incinerator'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_617301674e316.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Incinerator<\/span><\/a><br \/>\n<a class='yarpp-thumbnail' rel='norewrite' href='http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/hazardous-waste-incinerators-3' title='Hazardous Waste Incinerators'><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" src=\"http:\/\/www.hiclover.com\/ad\/wp-content\/uploads\/2021\/10\/20211022_61730167cf5e1.jpg\" class=\"attachment-thumbnail size-thumbnail wp-post-image\" alt=\"\" loading=\"lazy\" data-pin-nopin=\"true\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><span class=\"yarpp-thumbnail-title\">Hazardous Waste Incinerators<\/span><\/a>\n<\/div>\n<\/div>\n<div class='code-block code-block-5' style='margin: 8px 0; clear: both;'>\n<div class=\"klaviyo-form-SV65JQ\"><\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Capacity Not&nbsp;less&nbsp;than&nbsp;500Kg\/hr.Operation 24hr-7days\/week&nbsp;continuous&nbsp;operation.Combustion&nbsp;chamber 2&nbsp;combustion&nbsp;chamber.Temp. First&nbsp;combustion&nbsp;chamber&nbsp;800-1000&nbsp;C. Secandry&nbsp;combustion&nbsp;chamber&nbsp;1000-1200&nbsp;C,&nbsp;with&nbsp;the&nbsp;possibility&nbsp;to&nbsp;be&nbsp;upgraded&nbsp;to&nbsp;1400&nbsp;C.Combustion&nbsp;Efficiency 99.99%Retention&nbsp;time Of&nbsp;the&nbsp;flow&nbsp;gases&nbsp;not&nbsp;less&nbsp;than&nbsp;2&nbsp;Sec&nbsp;in&nbsp;the&nbsp;hot&nbsp;portion.Excess&nbsp;Oxygen&nbsp;concentration Of&nbsp;primary&nbsp;combustion&nbsp;chamber&nbsp;3-6%&nbsp;max. Refractory The&nbsp;chambers&nbsp;should&nbsp;be&nbsp;lined&nbsp;with&nbsp;high&nbsp;thermal&nbsp;insulating&nbsp;refractory&nbsp;bricks&nbsp;with&nbsp;suitable&nbsp;thickness&nbsp;and&nbsp;with&nbsp;highly&nbsp;temp.&nbsp;resistance.&nbsp;Not&nbsp;less&nbsp;than&nbsp;1400&nbsp;C&nbsp;for&nbsp;the&nbsp;first&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;not&nbsp;less&nbsp;than&nbsp;1600&nbsp;C&nbsp;for&nbsp;the&nbsp;secandry&nbsp;combustion&nbsp;chamber,&nbsp;and&nbsp;at&nbsp;the&nbsp;same&nbsp;time&nbsp;prevent&nbsp;the&nbsp;Temp.&nbsp;of&nbsp;the&nbsp;outside&nbsp;body&nbsp;of&nbsp;the&nbsp;chamber&nbsp;not&nbsp;higher&nbsp;than&nbsp;70&nbsp;C.Doors Should&nbsp;be&nbsp;lined&nbsp;with&nbsp;the&nbsp;same&nbsp;bricks,&nbsp;and&nbsp;the&nbsp;edges&nbsp;lined&nbsp;with&nbsp;special&nbsp;suitable&nbsp;insulating&nbsp;material&nbsp;to&nbsp;prevent&nbsp;any&nbsp;gas&nbsp;escaping,&nbsp;and&nbsp;the&nbsp;doors&nbsp;should&nbsp;be&nbsp;kept&nbsp;under&nbsp;negative&nbsp;pressure&nbsp;during&nbsp;the&nbsp;operation.Air&nbsp;Emission&nbsp;Control&nbsp;System With&nbsp;high&nbsp;destruction&nbsp;and&nbsp;removal&nbsp;efficiency&nbsp;(DRE).&nbsp;Not&nbsp;less&nbsp;than&nbsp;99.9999&nbsp;as&nbsp;per&nbsp;KEPA.Wet&nbsp;System If&nbsp;the&nbsp;system&nbsp;equiped&nbsp;with&nbsp;a&nbsp;CEMS&nbsp;washing&nbsp;the&nbsp;flow&nbsp;gas&nbsp;with&nbsp;water,&nbsp;then&nbsp;it&nbsp;should&nbsp;be&nbsp;manufactured&nbsp;from&nbsp;suitable&nbsp;anti&nbsp;corrossion&nbsp;materials,&nbsp;and&nbsp;equiped&nbsp;with&nbsp;pH&nbsp;meter&nbsp;to&nbsp;measure&nbsp;and&nbsp;neutralize&nbsp;the&nbsp;water.&nbsp;It&nbsp;should&nbsp;be&nbsp;able&nbsp;to&nbsp;use&nbsp;the&nbsp;water&nbsp;in&nbsp;closed&nbsp;recycled&nbsp;circuit&nbsp;many&nbsp;times&nbsp;before&nbsp;treating\/&nbsp;discharging&nbsp;into&nbsp;the&nbsp;sewage&nbsp;system&nbsp;in&nbsp;compliance&nbsp;with&nbsp;KEPARS.Chemical&nbsp;dosing It&nbsp;should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;suitable&nbsp;autochemical&nbsp;dosing&nbsp;system&nbsp;to&nbsp;control&nbsp;the&nbsp;pH&nbsp;for&nbsp;the&nbsp;water&nbsp;of&nbsp;the&nbsp;wet&nbsp;scrubber&nbsp;system&nbsp;including&nbsp;sensors.Chimney It&nbsp;should&nbsp;be&nbsp;suitable&nbsp;with&nbsp;the&nbsp;capacity&nbsp;and&nbsp;the&nbsp;technical&nbsp;specifications,&nbsp;with&nbsp;height&nbsp;not&nbsp;less&nbsp;than&nbsp;12m&nbsp;from&nbsp;ground&nbsp;level.&nbsp;With&nbsp;easy&nbsp;opennable&nbsp;sampling&nbsp;point&nbsp;equal&nbsp;about&nbsp;3&nbsp;inch,&nbsp;and&nbsp;the&nbsp;optimum&nbsp;sampling&nbsp;locations&nbsp;is&nbsp;at&nbsp;least&nbsp;8D&nbsp;downstream&nbsp;direction&nbsp;and&nbsp;2D&nbsp;upstream&nbsp;from&nbsp;any&nbsp;flow&nbsp;disturbancies.Sampling&nbsp;point Should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;a&nbsp;platform&nbsp;located&nbsp;down&nbsp;the&nbsp;sampling&nbsp;point&nbsp;by&nbsp;a&nbsp;distance&nbsp;not&nbsp;less&nbsp;than&nbsp;1&nbsp;m,&nbsp;and&nbsp;equiped&nbsp;with&nbsp;suitable&nbsp;stairs&nbsp;from&nbsp;ground&nbsp;to&nbsp;the&nbsp;port&nbsp;with&nbsp;comfortable&nbsp;slope.Ash&nbsp;Removal It&nbsp;should&nbsp;be&nbsp;auto&nbsp;ash&nbsp;removal&nbsp;system.Fuel It&nbsp;should&nbsp;be&nbsp;dual&nbsp;system,&nbsp;such&nbsp;as&nbsp;diesel&nbsp;and&nbsp;natural&nbsp;gas.Feeding&nbsp;System Should&nbsp;be&nbsp;auto&nbsp;feeding&nbsp;system&nbsp;into&nbsp;primary&nbsp;chamber.Control&nbsp;Room Should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;a&nbsp;control&nbsp;panel&nbsp;shows&nbsp;Temp.&nbsp;of&nbsp;the&nbsp;combustion&nbsp;burners,&nbsp;gas&nbsp;monitoring,&nbsp;digital&nbsp;Temp.&nbsp;indecation&nbsp;for&nbsp;the&nbsp;primary\/secondary&nbsp;chambers,&nbsp;digital&nbsp;Temp.&nbsp;indication&nbsp;for&nbsp;the&nbsp;gases\u2026etc.&nbsp;it&nbsp;should&nbsp;be&nbsp;also&nbsp;Auto&nbsp;operation,&nbsp;burnures&nbsp;on\/off&nbsp;auto&nbsp;lamps&nbsp;switch,&nbsp;auto&nbsp;start\/stop&nbsp;for&nbsp;air&nbsp;emission&nbsp;control&nbsp;system,&nbsp;auto&nbsp;gas&nbsp;continuous&nbsp;monitoring&nbsp;system&nbsp;reading&nbsp;and&nbsp;print&nbsp;out&nbsp;of&nbsp;gas&nbsp;emission&nbsp;parameters&#8230;etc.Cooling&nbsp;System The&nbsp;primary&nbsp;chamber&nbsp;should&nbsp;be&nbsp;provided&nbsp;with&nbsp;auto&nbsp;cooling&nbsp;systemthrough&nbsp;nozzles&nbsp;to&nbsp;permit&nbsp;direct&nbsp;cooling&nbsp;if&nbsp;the&nbsp;Temp.&nbsp;will&nbsp;be&nbsp;heigher&nbsp;than&nbsp;1100&nbsp;C.Inter-lock&nbsp;system The&nbsp;incinerator&nbsp;should&nbsp;be&nbsp;equiped&nbsp;with&nbsp;inter-lock&nbsp;system&nbsp;to&nbsp;prevent&nbsp;feeding&nbsp;the&nbsp;waste&nbsp;to&nbsp;the&nbsp;primary&nbsp;chamber&nbsp;if&nbsp;the&nbsp;combustion&nbsp;Temp.&nbsp;less&nbsp;than&nbsp;500&nbsp;C.Flue&nbsp;treatment&nbsp;and&nbsp;cleaning To&nbsp;consist&nbsp;a&nbsp;combined&nbsp;system&nbsp;(wet\/dry),&nbsp;using&nbsp;water,&nbsp;lime,&nbsp;active&nbsp;carbon&nbsp;and&nbsp;ceramic&nbsp;filters.Quenching&nbsp;system\/Heat&nbsp;exchanger Should&nbsp;be&nbsp;made&nbsp;and&nbsp;manufactured&nbsp;from&nbsp;anti&nbsp;corrosion&nbsp;and&nbsp;acid&nbsp;attack&nbsp;materials&nbsp;such&nbsp;as&nbsp;stainless&nbsp;steel&nbsp;316&nbsp;or&nbsp;equivalent.Noise&nbsp;Level Not&nbsp;more&nbsp;than&nbsp;85&nbsp;dBA&nbsp;during&nbsp;normal&nbsp;operation.Inaddition The&nbsp;desigh&nbsp;should&nbsp;insure&nbsp;that&nbsp;responsive&nbsp;fail-safe&nbsp;control&nbsp;systems&nbsp;are&nbsp;used. The&nbsp;incinerator&nbsp;should&nbsp;be&nbsp;installed&nbsp;inside&nbsp;closed&nbsp;suitable&nbsp;building&nbsp;with&nbsp;good&nbsp;aeration&nbsp;and&nbsp;ventilation&nbsp;system.&nbsp;The&nbsp;building&nbsp;has&nbsp;facilities&nbsp;for&nbsp;off-loading&nbsp;of&nbsp;wastes&nbsp;from&nbsp;transport&nbsp;vehicles.&nbsp;Auto&nbsp;cleaning&nbsp;system&nbsp;for&nbsp;trucks&nbsp;and&nbsp;waste&nbsp;containers,&nbsp;and&nbsp;cool&nbsp;storage&nbsp;area&#8230;etc. The&nbsp;quotation&nbsp;should&nbsp;included&nbsp;list&nbsp;of&nbsp;original&nbsp;spare&nbsp;parts&nbsp;for&nbsp;7&nbsp;years. The&nbsp;quotation&nbsp;should&nbsp;include&nbsp;supervising,&nbsp;starting&nbsp;up&nbsp;and&nbsp;training&nbsp;of&nbsp;the&nbsp;operators&nbsp;and&nbsp;ministry&nbsp;of&nbsp;health&nbsp;engineers&nbsp;inside\/outside&nbsp;Kuwait. Detailed&nbsp;drawings,&nbsp;catalogs&nbsp;should&nbsp;be&nbsp;included. Related posts: Leading Waste Incinerator Smallest Waste Incineration Into Energy System Incinerator Hazardous Waste Incinerators<\/p>\n","protected":false},"author":1,"featured_media":1118,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[1],"tags":[107,104,54,137,51,39,98,79,109,166,146,62,87,136,86,66,168,147,88,149,38,85,50,89,42,75,120,100,124,265,263,102,266,209,15,76,91,35,43,268,267,150,132,80,162,19,8,5,6,28,103,81,155,138,21,77,141,231,117,123,264,52,92,167,45,25,67,82,105,74,261,7,53,16,46,106,202,64,30,72],"class_list":["post-1117","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-incinerators","tag-107","tag-104","tag-a","tag-air","tag-an","tag-and","tag-are","tag-ash","tag-at","tag-bin","tag-brick","tag-build","tag-burn","tag-burner","tag-by","tag-ca","tag-can","tag-capacity","tag-chamber","tag-chemical","tag-clover","tag-co","tag-com","tag-d","tag-de","tag-des","tag-destruction","tag-di","tag-diesel","tag-drawing","tag-drawings","tag-en","tag-energy","tag-facilities","tag-for","tag-from","tag-gas","tag-hazardous","tag-hazardous-waste","tag-hazardous-waste-incinerator","tag-hazardous-waste-incinerators","tag-health","tag-hiclover","tag-high","tag-how","tag-in","tag-incineration","tag-incinerator","tag-incinerators","tag-is","tag-kg","tag-made","tag-materials","tag-mini","tag-of","tag-on","tag-para","tag-parts","tag-ru","tag-sa","tag-sewage","tag-small","tag-system","tag-that","tag-the","tag-to","tag-treatment","tag-un","tag-us","tag-use","tag-used","tag-waste","tag-waste-incineration","tag-waste-incinerator","tag-waste-incinerators","tag-wastes","tag-water","tag-with","tag-www","tag-y"],"_links":{"self":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/1117","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/comments?post=1117"}],"version-history":[{"count":1,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/1117\/revisions"}],"predecessor-version":[{"id":3393,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/posts\/1117\/revisions\/3393"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media\/1118"}],"wp:attachment":[{"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/media?parent=1117"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/categories?post=1117"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hiclover.com\/ad\/wp-json\/wp\/v2\/tags?post=1117"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}