Waste Management and Incineration Solutions at Beledweyne UNSOS Compound, Somalia
In Beledweyne, one of the key operational hubs for the United Nations Support Office in Somalia (UNSOS), proper waste management is critical to environmental protection and public health. The Beledweyne UNSOS Compound serves as a central logistics and mission support base for UN operations in the Hiiraan region, supporting peacekeeping, humanitarian, and reconstruction activities. Within this compound, a HICLOVER medical and solid waste incinerator has been deployed to ensure the safe and sustainable disposal of waste generated by the camp’s daily operations.
Reliable Incineration for UN and Field Operations
The HICLOVER incineration system installed at Beledweyne UNSOS Compound provides continuous and high-temperature treatment for mixed solid waste, including general camp refuse, packaging materials, and limited volumes of medical waste from clinic operations.
Operating temperatures reach over 1,100°C in the secondary combustion chamber, ensuring complete destruction of harmful organic compounds and pathogens. The twin-chamber configuration meets EU Directive 2000/76/EC and WHO guidelines for emission performance, while optional flue gas treatment units (wet scrubber, activated carbon, or bag filter) support environmental compliance.
Environmental Oversight and Audited Compliance
According to OIOS (Office of Internal Oversight Services) audits and environmental reports, UNSOS facilities across Somalia ― including those in Mogadishu International Airport, Baidoa, and Beledweyne ― use incineration systems to manage both hazardous and non-hazardous waste.
These installations are part of a broader UN environmental compliance framework emphasizing waste segregation, energy-efficient destruction, and reduction of open-burning practices. The Beledweyne site follows these principles by integrating a properly enclosed containerized incinerator, minimizing smoke, odor, and direct emissions to the surrounding community.
Engineering and Operational Highlights
-
System Type: Dual-chamber diesel incinerator (containerized)
-
Primary Chamber: Direct combustion of waste at 850C900 °C
-
Secondary Chamber: Gas re-burning at 1,100C1,200 °C for dioxin control
-
Fuel System: Dual-compatible Riello/Baltur burners with PLC automation
-
Throughput Capacity: Approx. 50C100 kg/hour (7C12 hours per day)
-
Emission Control: Optional wet scrubber, activated carbon tower, stack height ≥ 8 m
-
Application: UN base waste, clinical waste, packaging, and organic refuse
These specifications make HICLOVER a dependable solution for UNSOS, AMISOM, and other mission-critical operations seeking self-contained waste destruction units suitable for remote and semi-arid environments such as Beledweyne.
Broader UN and NGO Environmental Programs
UNSOS’s environmental initiatives extend beyond Beledweyne to other regional hubs like Baidoa and Mogadishu, focusing on plastic waste reduction, waste segregation at source, and clean-energy transition projects.
HICLOVER incinerators contribute to these goals by ensuring that medical and organic wastes are treated under controlled conditions rather than exposed to open burning or landfill contamination, aligning with UN Environment Programme (UNEP) and World Health Organization standards for field operations.
Commitment to Sustainable Operations
Deploying a HICLOVER incineration unit in Beledweyne underscores UNSOS’s commitment to maintaining operational hygiene and environmental safety in challenging field environments. As a containerized, mobile, and automated waste treatment solution, it supports continuous mission activities while minimizing the environmental footprint.
For more information about industrial and medical waste incinerators for UN, NGO, or humanitarian projects, visit:
Keywords: Beledweyne incinerator, UNSOS waste management, HICLOVER incinerator Somalia, UN environmental compliance, medical waste disposal Somalia, containerized incinerator, dual chamber incinerator, diesel incineration system, field waste treatment unit.
2025-11-08/20:50:40
|
Incinerator Items/Model |
HICLOVER TS100(PLC)
|
|
Burn Rate (Average) |
100kg/hour |
|
Feed Capacity(Average) |
150kg/feeding |
|
Control Mode |
PLC Automatic |
|
Intelligent Sensor |
Continuously Feeding with Worker Protection |
|
High Temperature Retention(HTR) |
Yes (Adjustable) |
|
Intelligent Save Fuel Function |
Yes |
|
Primary Combustion Chamber |
1200Liters(1.2m3) |
|
Internal Dimensions |
120x100x100cm |
|
Secondary Chamber |
600L |
|
Smoke Filter Chamber |
Yes |
|
Feed Mode |
Manual |
|
Burner Type |
Italy Brand |
|
Temperature Monitor |
Yes |
|
Temperature Thermometer |
Corundum Probe Tube, 1400℃Rate. |
|
Temperature Protection |
Yes |
|
Automatic Cooling |
Yes |
|
Automatic False Alarm |
Yes |
|
Automatic Protection Operator(APO) |
Yes |
|
Time Setting |
Yes |
|
Progress Display Bar |
3.7 in” LCD Screen |
|
Oil Tank |
200L |
|
Chimney Type |
Stainless Steel 304 |
|
1st. Chamber Temperature |
800℃–1000℃ |
|
2nd. Chamber Temperature |
1000℃-1300℃ |
|
Residency Time |
2.0 Sec. |
|
Gross Weight |
7000kg |
|
External Dimensions |
270x170x190cm(Incinerator Main Body) |
|
Burner operation |
Automatic On/Off |
|
Dry Scrubber |
Optional |
|
Wet Scrubber |
Optional |
|
Top Loading Door |
Optional |
|
Asbestos Mercury Material |
None |
|
Heat Heart Technology(HHT) |
Optional |
|
Dual Fuel Type(Oil&Gas) |
Optional |
|
Dual Control Mode(Manual/Automatic) |
Optional |
|
Temperature Record |
Optional |
|
Enhanced Temperature Thermometer |
Optional |
|
Incinerator Operator PPE Kits |
Optional |
|
Backup Spare Parts Kits |
Optional |
|
Mobile Type |
Optional:Containerized/Trailer/Sledge Optional |