Month: April 2024

Q: what is kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. Items/Model TS30(PLC) Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration  Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor […]
we supply incinerator for Kenya, with IDF SGS certification. the HS code of incinerator is 84178050. if you are looking for incinerator suppliers in kenya. please contact with us. we supply 10kgs per hour to 1000kgs per hour waste incinerators, with or without wet scrubber system. the burner is oil or gas type. We service and maintain our incinerators and provide consultancy services to Consulting Engineers, Mines, Abattoirs and Hospitals,  giving full details on the incinerator required and the price.   1. General waste incinerators for sale in Kenya. 2. Pet Cremation incinerators supply in Kenya 3. Bio-Medical Incinerators in Kenya […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Model YD-30  Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 kg/hour Gas Consumption (Natural Gas) […]
1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ). 2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk. 3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization […]
Waste Disposal Methods in Hospital • An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion and cool down cycle will take place overnight. • The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall […]
Primary chamber:Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic)  01 x temperature sensor points with complete internal fans.Secondary Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 02 Sec gas residence times.Third Chamber:Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal fans. 02 Sec gas residence time.Integrated dual flu gas washer: Resultant gasses passed through dual gas filtration system for maximum clean emission. It is also equipped with chain filters.Chimney:Heavy duty 5mm or more stainless steel casing mild steel casing.Stack cap/spark arrestors.Control Panel:a.Temperature Monitoring with 4 digit display.b.Thermostat control device for burner (fuel saver)c.Temperature control 0-12 hours.d.Integral fan timer control
Hiclover supply medical waste incinerators with capacity 10kgs per hour to 500kgs per hour.  The incinerator with dual/double combustion chamber and dry filter chamber, two fuel burner from  Italy manufactured, hot sale model for small scale waste output, the capacity is 30kgs per hour  and 50kgs per hour. We are famous small scale incinerator manufacturer […]
Model A1500 (customer made model) Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Optional Part) Incinerator Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy oil […]
Incinerator for Animal Crematory Pig Farm Model A1200 *** 3 sets Burners *** Good for animals or big pets *** Double Combustion chamber *** stainless steel chimney *** Italy made oil burners *** 1200Liters(1.2m3) big chamber Model A1200 Picture Burning Rate Average 50 kgs/hour Feed Capacity Average 100 kgs/feeding Primary Combustion Chamber 1200 Liters Secondary […]
Items/Model CA100 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 1.3 Kw Oil Consumption (kg/hour) Average 20.4 Kgs/Hour Gas Consumption (m3/hour) *** Temperature […]
Waste Incinerator (Containerized Mobile Incinerator) Capacity: Average 50 kgs per hour Model CA50 Internal Dimensions 100 x 80 x 70 cm Main Product List Primary Combustion Chamber Secondary Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil/gas burner: 02 units Oil Tank (if oil fuel): 200Liters ISO […]
We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
How much fuel does an incinerator use? Most fuel-assisted incinerators with a capacity to destroy 100 to 150 kilograms of waste per day consume 5 to 8 liters per hour of fuel (4 to 6.5 kilograms of gas)   What are three disadvantages of incinerators? Disadvantages of Waste Incineration     It is Expensive. The installation of an incineration plant is an expensive process. …     Pollutes the Environment. …     Damaging Public Health. …     The Possibility of Long-term Problems. …     Ash Waste Can Potentially Harm People and the Environment. …     Environmental Racism. smart ash incinerator incinerator diesel incinerator south africa package medical waste incinerator   How much does it cost to run an incinerator? Cost of incineration plant by formula According to the formula, the cost of a 40,000 tpa plant is $41 million, or $1,026 per ton of annual capacity. A Medium-sized 250,000 tpa plant should cost $169 million, or $680 per ton of annual capacity. These numbers give us the first estimation of how much waste-to-energy is.   How hot is an incinerator? Thermal destruction of most organic compounds occurs between 590/C and 650/C (1100/F and 1200/F). Most hazardous waste incinerators are operated at 980/C to 1200/C (1800/F to 2200/F) to ensure nearly complete destruction of the organics in the waste (AWMA, 1992). Why incinerators are the most expensive form of waste disposal? Incineration is generally the most expensive form of waste disposal because incin- erators require a lot of energy to operate. Incinerators also need pollution-control devices and need to be carefully monitored so that hazardous gases and particles are not released into the air.       Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. PLC […]
This equipment quality structural for kinds of site, like hospital, environmental department,  animal cremation agencies, etc.  HICLOVER Incinerator supply updated models with dual combustion chamber,  mix-combustion chamber and smoke filter  chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Equipment Technical Specifications Model YD-10C Picture Feed Capacity Average 40 kgs […]
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour *(50/100/200kgs/hour […]
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Item Serie No. Part Name Packing List 1# Incinerator Mainbody   2# Oil Tank(Deposit)   3# Oil Tank(Daily)   4# Chimney(Vertical,High Temperature)   5# Chimney(Horizontal,High Temperature)   6# Wet Scrubber   7# Chimney(S shape)   8# Chimney(Below)   9# Chimney(Top) Hospital Incinerators for Medical […]
News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus  WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak, as the country reported 830 confirmed cases of pneumonia, caused by the virus and 25 deaths by the end of Thursday (Jan 23). By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed […]
HICLOVER Medical Environmental Incinerators|Phone/WhatsApp:+86-13813931455  |Web: http://hiclover.com |#COVID19|#incinerator|#waste|#medical| Medical Waste Incinerator TECHNICAL SPECIFICATION FOR SUPPLY AND INSTALLATION OF MEDICAL  WASTE INCINERATOR AT MAHAMA HEALTH CENTER http://video.hiclover.com/hiclover-plc-auto-waste-incinerator-controller-setting-2021/  Items/Model TS30(PLC) Picture   Brand HICLOVER Burn Rate Average 30-50 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Dry Scrubber […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator 100kg per hr 5. INDOOR INCINERATOR HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration […]
  Incinerator Items/Model HICLOVER TS30(PLC) Burn Rate (Average) 30-50 kg/hour Feed Capacity(Average) 60kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V 2P Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) 12 N.Gas Consumption (m3n/hour) 9.8–20 Temperature Monitor Yes Temperature […]
Medical Waste Incinerator for Coronavirus Disease( COVID-19).    * Full variety incinerator with Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.  * Single burning chamber, double combustion chambers, three combustion chambers and also multi-combustion chambers waste incinerators.  * System solutions for clinical waste environmental.  * High […]
Small Waste Incinerator, 10kgs per hour capacity, PLC control Items/Model TS10(PLC) Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) average 8.4kg/hour Gas Consumption (m3/hour) average […]
Design for Pets Cremation Business Movable platform & Auto. Door Independent Position for Small Pet Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business Model A1500 Picture Burning Rate Average 150 kgs/hour Feed Capacity Average 350 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour […]
Model YD-30M Primary Combustion Chamber Secondary Combustion Chamber Mix Combustion Chamber Smoke Filter Chamber Incinerator  Control Case Stainless Steel Chimney: 1.5 Meter Italy oil/gas burner: 02 sets Oil Tank (if oil fuel): 100Liters Video material: https://twitter.com/i/status/1279030799182905345  Model YD-30M  Picture Burning Rate  average 20 kgs/hour Feed Capacity average 40 kgs/feeding Paimary Combustion Chamber 200 Liters Secondary […]
Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural […]
The equipment proposed shall be an incinerator specialised for Medical Wastes.  Medical waste may consist of discarded materials or equipment contaminated with blood and its derivatives, other body fluids or excreta from infected patients with hazardous communicable, contaminated waste from patients known to have blood-borne infections undergoing haemodialysis (e.g dialysis equipment such as tubing and […]
Incinerator Model YD-30 for Australia Melbourne customer. From year 2011 to 2013, we delivery 02 different model for this customer, one is model SYC-50 (now updated to Model TS50 PLC) and one model YD-30. Both two model is gas fuel type and these incinerator for local family pet cremation business. Items/Model YD-30 Burning Rate (kgs/Hour) […]
we use latest incinerator technology with high temperature combustion with 2 or 3 chambers, with wet scrubber or dry scrubber system and auto control system incinerator.   medical waste incinerator spare parts in stock for our customer, including air fan, burners, control case, temperature element.  the small scale equipment for laboratory incinerator specification like 10kgs per hour is hot sale in market, we supply cheap cost. […]
CONTAINERISED WASTE INCINERATOR Incinerator Items/Model HICLOVER TS150(PLC) Picture   Burn Rate (Average) 100-150 kg/hour Feed Capacity(Average) 300kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 1500Liters(1.5m3) Internal Dimensions 1500x1000x1000mm Secondary Chamber 750Liters(0.75m3) Smoke Filter Chamber Wet Scrubber Feed Mode Manual/Mechanical Voltage 415V 3P Power 10.0Kw 3.1. THE PRESENT SITUATION IN SOUTH SUDAN IS HOSTILE, UNPREDICTABLE AND […]
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50(PLC) Picture   Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Optional Upgrade Containerized Mobile Type Incinerator ISO 20′ Full Container Combustion Chamber 560L Internal Dimensions 1000x800x700mm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/240V 50Hz 1P […]
Items/Model TS30(PLC) Picture   Burn Rate Average 30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Auto Control and Display Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3 Gas Consumption (N.G, m3n/Hour) […]
Sources of Healthcare Waste •Hospitals •Clinics •Laboratories •Research activities •Nursing homes •Acupuncturist •Paramedic and ambulance services •Animal research •Blood banks • Mortuaries •Autopsy centers Other Sources of Healthcare Wastes •Physicians’ offices •Dental clinics •Chiropractors •Psychiatric hospitals •Cosmetic piercing and tattooing •Institutions for disabled persons •Funeral services •Home healthcare •Define healthcare waste •Describe sources and examples of healthcare waste •Describe general characteristics of healthcare waste •Identify where wastes are generated in your facility •Categorize the wastes into two general categories based on whether or not they pose a risk •Describe general characteristics of the wastes Definition of Healthcare Waste What is healthcare waste? – Total waste stream from major healthcare establishments and from minor scattered healthcare activities General Types of Healthcare Waste Healthcare waste can be –Non-hazardous general wastes comparable to domestic waste (75-90% of healthcare waste in a health facility) –Potentially hazardous waste or waste that is associated with some health risks (10-25% of healthcare waste in a health facility) Sources of Healthcare Waste •Hospitals •Clinics •Laboratories •Research activities •Nursing homes •Acupuncturist •Paramedic and ambulance services •Animal research •Blood banks • Mortuaries […]
Items/Model TS250(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 210x88x110cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Average 24.2(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display […]
Curing Duration,need a small incinerator, they discard 100 liters of covid masks daily.batch load, direct fire,  mobile incinerator for a variety of applications including medical waste. The unit is one of the lightest in its class ,  facilitating deployment for virus outbreaks and disaster relief operations. Primarily running on diesel 1. Where can I watch a video of a real-life application? 2. The modulating under air burners ensure consistent high temperatures needed to destroy infectious waste,  whilst retaining the flue gas for sterilization. Simply load waste into the chamber, close the door and turn on the unit. 3. When approved and paid for, how many days for shipment? 4. As per the requirement we have ordered an Incinerator that can process 100kg hospital waste and as per the  end user they are only able to put 3 bags of waste which are approximately 10kg each. So we are only able to  process 30 Kg of waste instead of 100Kg. As per the hospital the chamber volume is very small and can not process 100kg hospital waste 5. Can you give me the listing of extras needed, and  installation of the TS150 PLC Incinerator and am in  need of technical assistance? 6. What are the most commonly needed repair parts?a)   Waste Auto Loading Ram Hopper  b)   Standard Tools (What the tools are there?, Please figure out) c)   Recommended spare parts (1 year) (such as burner, refactor cement, temperature probe, etc.) d)   Commissioning and Training  e)   Support wires, clamp and bracket as chimney is 33 m height              HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification. Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)   Waste Incinerator RFQ(Request for Quotation) http://www.hiclover.com/ad/rfq/   EStore for Waste Incinerators http://www.haiwos.com   2022-06-24 […]
Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 230 x 100 x 90cm (primary chamber) External Dimensions 290 x 200 x 170cm […]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Equipment Technical Specifications Model TS30S Picture   Feed Capacity 78 Liters for primary chamber Burning Rate Average 30 kgs per hour Burning Time per Feed 0.5 hour Voltage 220V Power 0.5Kw Fuel Diesel oil Burner Diesel Oil Burner, 2 sets Feed Mode Manual Fuel consumption (Oil) Average 8 Kgs/Hour External Dimensions 90 x 90 x […]
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour  Oil tank smoke filter chamber Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1000L Internal Dimensions 120x100x90cm Secondary Chamber 540L Smoke Filter Chamber Optional Feed […]
100 Kg/Hr Bio-Medical Waste Incinerator, wet scrubber/spary tower optional. 2 combustion chambers, italy burner, APO function,    PLC auto control system incinerator   Incinerator Items/Model HICLOVER TS100(PLC)   Burn Rate (Average) 100-150 kg/hour Feed Capacity(Average) 200kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V […]
Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. to 500kgs/Hr., up […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like […]
Average 30kgs per hour ***Primary chamber(200Liters) *** Secondary chamber *** Mix combustion chamber *** Stainless steel chimney(1meter) *** Italy made oil burner(2sets) *** Dry Scrubber *** Weight 1.7T(can reduce to 1.0Ton) Main Spare Parts(Standard for incinerator, and price include already): *** 2 sets Italy Oil Burner *** 2sets Temperature Probe *** 1 set Control Case […]
Model TS30 oil fired waste small incinerator 30kgs/hr. Items/Model TS30(PLC) Picture   Burn Rate Average 20-30 kg/hour Feed Capacity Average 60kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 330L Internal Dimensions 75x75x60cm Secondary Chamber 180L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5Kw Oil Consumption (kg/hour) Average 13.3 […]
Heat Resistant Gas Rope for incinerator installation, feeding door, chimney sealing,etc. non-asbestos material Ceramic Fiber Sealing Rope  Sealing Rope for waste incinerators WWW.HICLOVER.COM Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC) Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding Control Mode PLC Automatic PLC […]
Vertical closed furnace combustion chamber incinerator   Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal hospital bed supplies, general wastes.   10-20kg/time (daily burn 3-6times, each time consume about 1 hour) total daily waste capacity 120 kg   Incinerator Items/Model HICLOVER TS10(PLC)   Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V 2P Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) […]
Incinerator Items/Model HICLOVER YD30(PLC)     Burn Rate (Average) 15kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 360L(0.36M3) Internal Dimensions 100x60x60cm Secondary Chamber 200L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V  Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) 12 N.Gas Consumption (m3n/hour) 9.8–20 Temperature Monitor Yes Temperature Thermometer […]
Incinerator Model A1500, Overview This model is big-scale animal cremation equipment for big animals.  Construction is dual/double combustion chamber with 03 units oil/gas burner,  batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500).  Primary & Secondary combustion chambers and included mix-combustion chamber,  smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load […]