Heavy duty firebrick for incinerator chamber 55% of Al203 65% of Al203 75% of Al203 Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 100L 210L 330L 560L Internal Dimensions 50x50x40cm 65x65x50cm […]
Incinerator Model CA100, Overview 100Kg/Hour Burning rate with Secondary burning Capacity This model is small-scale medical waste incineration equipment. Construction is dual/double  combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed  chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke  filter chamber with firebrick and  refractory concrete chamber. Batch […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like […]
Items/Model TS50(PLC) Picture Principle Medical Waste Incineration,dual chamber incinerator Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor Digital Display Temperature Protection Yes […]
HICLOVER Top Feeding Door Waste Incinerators ***Primary Combustion Chamber ***Secondary Combustion Chamber ***Smoke Filter Chamber ***Optional Wet Scrubber System(1 section or  3 sections) ▲▲▲Large Feeding Door ▲▲▲Better for Animal Waste Cremation ▲▲▲HICLOVER Brand Section Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Items Side Loading Door Top Loading Door Cost Cheap High cost Manufacture Tech. Easy A litter difficult […]
○ Containerized Mobile Incinerator(CA Model) HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities […]
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless […]
Item Specification Model YD-20C Main Product List   Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters   Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. bio medical waste management ppt 2020 HICLOVER Incinerator/Parts Range Main Feature Medical […]
30kgs per hour(average) medical waste incinerator, design dual  combustion chambers(primary chamber and secondary chamber),  smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small  hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Principle Waste Incineration Burn Rate Average 30kgs/hour Fuel Type Diesel Oil/Natural […]
Each incinerator shall be supplied with all necessary assembly/disassembly tools. Spare parts and consumables The proposed incinerator systems shall include all  necessary spare parts, PPE, and consumables required for 2 years of operation.  https://twitter.com/i/status/1578045332285698049  Incinerator Items/Model HICLOVER YD30(PLC)   Burn Rate (Average) 30-50kg/hour(Medical Waste) 10-15kg/hour(Pet Animal Cremation) Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary […]
biohazard waste disposal guidelines 1. The ground should be flat when install the incinerator. There should be 100cm at least between the incinerator  and the walls on the two sides and the back, which is in convenient maintenance and repair. 2.  A), Place the incinerator main body(combustion chamber) and fixed with bolts and Asbestos tape. B), Place the wet scrubber system and fixed with bolts and Asbestos tape. C). Install chimneys and fixed with bolts, Asbestos tape and Steel Rope. D). Fix the incineration house roof. E). Fix burner, blower, wind tube, electric system, fuel system. 3. Check the electric wire: the incinerator’s electric circuit should be linked with the ground wire to guard against current leakage.  The link-up of the electric wire should be checked carefully before starting the incinerator, in case of wrong link-up or leakage. 4. Check of the fuel supply system: Except the Burner’s soft pipe which is used for the fuel flowing-in and flowing-back, all the rest pipes must use brass or steel pipe. No leakage is allowed at pipe junctions. Any leakage should be blocked in time. 5. Install steel rope with the chimney, to avoid tilt by wind.  6. Install net cover at the blower, to avoid sundries. 7. If the fuel is Natural Gas with gas burner, please contact with local administration section and install gas supplier system. 8. Crane or forklift is necessary when download/upload/install incinerator.  9. Topped work house roof after installation. 10.Get the video material: http://www.eclover.net/category/incinerator-video/     Nanjing Clover Medical Technology Co.,Ltd. incinerate china orders incinerators hospital waste disposal ppt safe waste incinerator company medical sharps disposal services in kenya Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. […]
*** Primary combustion chamber & secondary combustion chamber *** Smoke filter chamber(dry scrubber) *** stainless steel chimney *** PLC auto. control *** Italy made oil or gas burner(diesel oil/natural gas/lpg) *** temperature display and control *** high temperature firebrick,etc Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 […]
Item Specification Model YD-20C Main Product List   Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters   Optional: Mobile Trailer for Incinerator Mobile Type Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion […]
incinerator for poultry farm dead checkin 575 kg, HICLOVER YD50 incinerator or TS50     Model YD-50 Picture   Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 700 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.8Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original […]
Diesel Oil Filter Cup   on Oil Line for Incinerator Can I burn paper in a garden incinerator? Basically, just like you would when making a bonfire. If filled correctly with  dry material, the incinerator will only take a few moments to light.  I use long matches that can be poked through the holes in the […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Model YD-100 Picture Burning Rate 100-150 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chamber 500 Liters Feed Mode Manual Voltage 220V/380V Power 2.5Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 28 kg/hour Gas Consumption (Natural Gas) *** Internal Dimensions 180x115x98 cm (primary chamber) External Dimensions 270x185x280cm (without chimney) Temperature […]
Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture   Principle Medical  Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) *** […]
having waste from production process which is having very fine/powder material with moisture of 40%. Will this machine suitable for this application. For power waste, proposal plus wet scrubber system. Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust.   Optional 3 section type: Wet Cooling Spray Scrubber+Wet Dust Scrubber+Fog and Water Separator. […]
SIEMENS Control Unit for OIl Burner  LOA24.171B27  Spare Parts for Incinerator Burner What can be burned in an incinerator? A material commonly associated with waste incineration is municipal solid waste (MSW).  This type of waste is typically general waste such as household waste, food waste,  cardboard, and paper. All of these are safe to incinerate. […]
Items/Model TS1000 Picture   Principle Waste Incineration Treatment Burn Rate Average 1000 kg/hour Feed Capacity Average 3000kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 4800Liter Internal Dimensions 400*120*100 cm Secondary Chamber 1000Liter Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) Average 67(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil […]
Items/Model HICLOVER TS150(PLC) (Mobile Type) N1155 Picture  mobile incinerator Principle Waste Incineration Treatment,trash incinerator Burn Rate Average 150 kg/hour Feed Capacity Average 150kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) […]
Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour […]
BURNING RATE : -100-150kgs per hour MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY : COMPULSORY DENSITY INSULATION : 50 mm high Refractory capacity : min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME : […]
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion,Medical waste management pdf. The […]
Incinerator for Medium type Hospital 100 -200 Kg per day incineration at south of switzerland fabrication incinerateur waste to energy technologies elastec incinerator hospital waste management Incinerator Items/Model TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed […]
  pictures of 500kg per hour machine   Items/Model TS500(PLC) Picture   Principle Medical Waste Incineration Treatment how many burners does the primary have Burn Rate Average 500 kg/hour,if 500kg has 1 burner Feed Capacity Average 500kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L Internal Dimensions 190x120x120cm Secondary Chamber 1300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power […]
Item Specification Model YD-30C (customer made model) Main Product List Primary Combustion Chamber(Main body stainless steel) Secondary Combustion Chamber(Main body stainless steel) Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Main body stainless steel) Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy gas burner: 02 units Oil Tank (if oil fuel): 100Liters Model YD-30C Feed […]
you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to […]
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including […]
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. Incinerator Model TS10 PLC, Overview   This model Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 100Liters (0.1m3, TS10 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Items/Model TS10(PLC)       Picture   Burn Rate Average 10 kg/hour Feed Capacity Average 20kg/feeding Control Mode Programmable Logic Controller(PLC) Panel Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage […]
Advantages of Waste Incineration     Decreases Quantity of Waste. …     Efficient Waste Management. …     Production of Heat and Power. …     Reduction of Pollution. …     Incinerators Have Filters For Trapping Pollutants. …     Saves on Transportation of Waste. …     Provides Better Control Over Odor […]
Model WS-35 Picture Burning Rate Average 35 kgs/hour Feed Capacity Average 80 kgs Primary Combustion Chamber 460 Liters Secondary Combustion Chamber 200 Liters Third Combustion Chamber 200 Liters Smoke Filter Chamber Wet Scrubber System Feed Mode Manual Voltage 220V Power 2Kw Fuel Type Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) *** Gas Consumption […]
Waste Incineration Treatment Diesel Oil type Model TS150 Main Parts List as below: Primary combustion chamber Secondary combustion chamber smoke filter chamber incinerator PLC control case chimney, 10meters, stainless steel Italy Oil fule burner oil tank 300liters with full spare parts: oil burner, air blower, temperature thermocouple
Incinerator, incineration equipment to burn material you want to burn. most of time, Incinerator for waste burning, including solid waste, liquid waste and gas waste. the Incinerator fuel including oil, gas, coal, wood, etc. the fuel function for start burn, keep waste burn or only keep burn itself to get high temperature. Incinerator request 1/2/3/more […]
Items/Model TS75 Picture   Principle Solid Waste Incineration  Burn Rate Average 75 kg/hour Feed Capacity Average 100kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 600L Internal Dimensions 100x60x100cm Secondary Chamber 300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (L/Hour) 15-20 Natural Gas Consumption (m3n/hour) ** Temperature Monitor Digital Display Temperature […]
Average 50-100 kg/hour Burn Rate   Items/Model TS75(PLC) Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Face Oil Paint 800℃ Combustion Chamber 768 Liters (0.768M3) Internal Dimensions 1200x800x800mm Secondary Chamber 384 Liters (0.384M3) Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/240V 50Hz 1P […]
Items/Model TS300(PLC) Principle Waste Incineration Treatment Burn Rate Average 250 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.5Kw Oil Consumption (kg/hour) Average 28(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank […]
Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture   Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) Average 24.2(D.O) Gas Consumption (m3n/hour) Average 21.3(LPG) Temperature […]
Smallest Waste Incinerator for PPE waste face mask glove waste Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney ave 10kgs per hour, 100kgs per day(10hr/day working) Equipment Technical Specifications Model YD-10 Picture   Feed Capacity Average 20 kgs per feeding Burning Rate Average 10 kgs per hour Burning Time […]
Items/Model TS500(PLC) Picture   Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700Liters (2.7m3) Internal Dimensions 190x120x120cm Secondary Chamber 1300Liters (1.3m3) Smoke Filter Chamber Dry Scrubber Chamber Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (kg/hour) Average 44(DO) Gas Consumption (m3n/hour) Average 53(NG) Temperature Monitor Digital […]
Model A1500(Movable platform & Auto. Door) Picture   Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) Average 34 kg/hour […]
Mobile Containerized Waste Incinerators pets or human cremation emergency use   Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 200 x 100 x […]
50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Model YD-50  Burning Rate Average 50 kgs/hour Feed Capacity Average 150 kgs Primary Combustion Chamber 900 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke […]
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: [email protected][email protected]   Nanjing Clover Medical Technology Co.,Ltd. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation Equipment For Pet(small/big) Cremation Business Animal Incineration Equipment For other animal incineration Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. […]
High Temperature Protection Gloves and  High Temperature Protection Masks for incinerator operation Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   how to incinerate aerosol spray incinerator for sanitary napkins for schools dial thermometer for incinerators mobile incinerator medical waste what are the costs and benefits of building a brick incinerator for hospital drum inceniration Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) […]
hazardous waste disposal incinerator http://www.military-camps-incinerator.com/  Incinerator Items/Model HICLOVER TS100(PLC) HICLOVER TS150(PLC) Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour Feed Capacity(Average) 200kg/feeding 300kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) 1500Liters(1.5m3) Internal Dimensions 120x100x100cm 1500x1000x1000mm Secondary Chamber 600L 750Liters(1.0m3) Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V Power 0.7Kw […]
Q: what is kind of waste can use in this equipment?A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any  explosive and radiation material, liquid waste and gas waste. Q: Incinerator Smoke StandardA: China Government Standard: No.GB18484-2001. Q: Treatment capacityA: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),  not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.   Clover incinerator use time per day up to 24 hours. Between each feed/combustion time,  there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion  time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.  Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour.  When incinerator use in hospital, please calculate the waste output capacity around 2kgs  per people per day. If there are 200 sickbed in the hospital, that’s mean you need one  incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs  per hour. According the operation time per day, waste material, budget,  development, etc, you can use capacity from 30-50 kgs per hour incinerator.*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. Q: Assembly and TestingA: We supply all documents and incinerators easy to installation and operation. Customer  can send people come to our factory to learn installation and operation. Generally,  We do not send engineer to local site if not request. The dispatch cost is extra according to order. Q: Combustion TemperatureA: The first combustion chamber: 800-1000 centi degree.The second combustion chamber: 1000-1200 centi degree. Q: Incinerator Control ModeA: Default Control mode is common control case. PLC mode according to model and order. Q: Operation and maintenance costsA: Operation cost according to fuel consumption rate and power/staff, etc.  Annual around $500-$1000usd per year maintenance according model, use situation.  One person can service 02 unit incinerators. The staff should have basic electrician  knowledge to operate/inspect/maintaince incinerator/burner/blower according to  operation user guider, and know risk of medical waste to protect worker self with necessary protection element. Q: The Residency time in secondary combustion chamber A: 02 sec. WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com  Email: [email protected][email protected]   Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour […]
Diesel Biogas Dual Chamber Incinerator, with diesel oil and Biogas burner    Incinerator Items/Model HICLOVER TS50   Burn Rate (Average) 50 kg/hour Feed Capacity(Average) 100kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Dual chamber up to 50 kg per hour semi-automatic Independent control of primary and secondary temperatures via control panel 850 -1100 C 1000- 1200 C >= 2 seconds <5% Electronic control panel providing friendly interface for operators with minimal training Mobile: +86-138139 31455(WhatsApp) Website: www.hiclover.com  Email:     [email protected]        Email:    […]