Nanjing
Clover Medical Technology Co.,Ltd.
Tel:
+86-25-8461 0201
Fax:
+86-25-8461 0406
Website:
www.cloveridea.com.cn
Email:
cloverincinerator@Gmail.com
About Us
Small Incinerator
Incinerator YD10C
Incinerator YD20C
Incinerator YD30C
Incinerator YD50C
Medical Incinerator
Incinerator YD30
Incinerator YD50
Incinerator YD100
Incinerator YD150
Incinerator YD300
Incinerator YD500
Incinerator YZ20
Incinerator YZ50
Incinerator YZ100
Incinerator YZ150
Animal Cremation
Incinerator Burn Rate
10kgs per hour
20kgs per hour
30kgs per hour
50kgs per hour
100kgs per hour
150kgs per hour
300kgs per hour
500kgs per hour
Incinerator Burner
Light Oil Burner
Gas Burner
YZ Incinerator
Certificate
How to Buy Incinerator
Market Analytics
Contact Us
¡¡
¡¡
¡¡
¡¡
|
CLOVER Incinerator
Call us on 0086-25-8461 0201
[email protected]
China Medical Incinerators /
Animal Cremation / Waste Incinerators
¡¡
Model |
YD-30 |
Burning Rate |
30 kgs/hour |
Feed Capacity |
60 kgs |
Paimary Combustion Chamber |
360 Liters |
Secondary Combustion Chamber |
200 Liters |
Mix Combustion Chamber |
Yes |
Smoke Filter Chamber |
Yes |
Feed Mode |
Manual |
Voltage |
220V |
Power |
0.59Kw |
Fuel Type |
Diesel Oil/ Natural Gas/LPG |
Burner |
Italy Original |
Oil Consumption (Diesel Oil) |
10.2--19.8 kg/hour |
Gas Consumption (Natural Gas) |
9.8--20 m3/hour |
Internal Dimensions |
100 x 60 x 60cm (paimary chamber) |
External Dimensions |
145 x 90 x 260cm (without chimney) |
Temperature Monitor |
Yes |
Oil Tank Capacity(if oil fuel) |
200 Liters |
Door Opening |
48 x 60cm |
Chimney Length |
5.0 Meters |
Chimney Type |
Stainless Steel |
Equipment Gross Weight |
2300 kgs |
Operation Technical Specifications |
Paimary Chamber Temperature |
800¡æ--1000¡æ |
Secondary Chamber Temperature |
1000¡æ-1200¡æ |
Residency Time |
2.0 Sec. |
Burning Efficiency |
£¾98% |
Waste Lower Calorific Power |
3000Kcal |
No. Technical
Specification
1 ¡°The Chamber volume of approximately
0.37m3 and a
1 combustible load volume (volume of
material) of
approximately 0.30 m3¡å
2 Burner power of approximately
189,000kcal/hour
3 Maximum Combustion Temperature of up
to 1250 Degree Celsius
4 Type of emitted Gas: Inert and nil
environmental pollution effect
5 Electrical Power: 220V/50 or 60
Hertz¡ª220V/50Hz
6 Fuel: Diesel
7 Electrical consumption of
approximately: 0.35 kw/hr
8 Fuel consumption range: 7 ¨C 11 ltrs/hr
9 Controls: Incinerator control
including control panel, timer, display
for monitoring combustion temperature,
system error display, etc.
10 Packaging/Installation: Incinerator
fully assembled and ready to be plugged
in power source
11 ¡°Instruction manual: Package must be
provided with instruction manual
including detailed information to
installation, operation, maintenance,
interpretation of trouble shooting
signals and contact telephones
numbers/emails of local or overseas
manufacturer¡¯s technicians that can be
contacted for guidance on operation of
the equipment, if necessary.¡±
12 ¡°Instruction manual: Package must be
provided with training guide/manual on a
compact disc including a demonstration
for installation, operation and
maintenance, as well as safety
guidelines, etc.¡±
13 ¡°Scope of Supply: Package must be
provided including
all the required accessories for
installation and must
include spare parts/consumables that are
required for a
one year period at a combustion rate of
up to 8 hours
daily¡±
14 ¡°Warranty must be provided for a
5-years period
starting with the incinerator¡¯s
installation and
including the provision of accessories
and
consumables¡±
¡¡
|
¡¡ |
¡¡ |