Clover Incinerator

Nanjing Clover Medical Technology Co.,Ltd.        

¡¡ ¡¡
¡¡ Call us on  0086-25-8461 0201  [email protected] ¡¡

 

¡¡ ¡¡ ¡¡ ¡¡




¡¡



¡¡

¡¡

 Nanjing Clover Medical Technology Co.,Ltd.
 Tel: +86-25-8461 0201
 Fax: +86-25-8461 0406

 Website: www.cloveridea.com.cn
 Email:
cloverincinerator@Gmail.com

About Us

Small Incinerator

Incinerator YD10C

Incinerator YD20C

Incinerator YD30C

Incinerator YD50C

Medical Incinerator

Incinerator YD30

Incinerator YD50

Incinerator YD100

Incinerator YD150

Incinerator YD300

Incinerator YD500

Incinerator YZ20

Incinerator YZ50

Incinerator YZ100

Incinerator YZ150

Animal Cremation

Incinerator Burn Rate

10kgs per hour

20kgs per hour

30kgs per hour

50kgs per hour

100kgs per hour

150kgs per hour

300kgs per hour

500kgs per hour

Incinerator Burner

Light Oil Burner

Gas Burner

YZ Incinerator

Certificate

How to Buy Incinerator

Market Analytics

Contact Us

¡¡

¡¡

¡¡

¡¡

¡¡

CLOVER Incinerator

Call us on  0086-25-8461 0201  [email protected]

China Medical Incinerators /  Animal Cremation / Waste Incinerators

 Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc.

The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion.

Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell.

The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation.

In some Developed countries, some new waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.

Model YD-150 
 Burning Rate  150 kgs/hour
Feed Capacity 300 kgs
Paimary Combustion Chamber 1500 Liters
Secondary Combustion Chamber 500 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 1.03Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 17--36 kg/hour
Gas Consumption (Natural Gas) 11--36.7 m3/hour
Internal Dimensions 150 x 100 x 96cm (paimary chamber)
External Dimensions 240 x 170 x 380cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 59 x 81cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 7000 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800¡æ--1000¡æ
Secondary Chamber Temperature 1000¡æ-1200¡æ
Residency Time 2.0 Sec.
Burning Efficiency £¾98%
Waste Lower Calorific Power 3000Kcal

¡¡

¡¡

¡¡ ¡¡