¡¡

Nanjing Clover Medical Technology Co., Ltd.

¡¡ ¡¡
¡¡ Medical Incinerators /  Animal Crematory / MSW Incinerators ¡¡

 

¡¡ ¡¡ ¡¡




¡¡



¡¡

¡¡      
   ººÓï   
   English   
   P§å§ã§ã§Ü§Ú§Û ¡¡

 Nanjing Clover Medical Technology Co.,Ltd.
 Tel: +86-25-8461 0201
 Fax: +86-25-8461 0406
 Website:
www.clover-incinerator.com
 Email:
[email protected]
 Email:
[email protected]
 Service Skype ID: clover-incinerator

>About Us

>Company NewsNew

>Newsletters April 2012 (PDF)

>Catalogue 2012  (PDF)

>Incinerator Models

>Medical Incinerators

>MSW Incinerators

>Small Incinerators

>Pet Crematory

>Smoke Dust FilterNew

>Contact Us

 Medical Incinerator

¡î Model YD-30 Incinerator

¡î Model YD-50 Incinerator

¡î Model YD-100 Incinerator

¡î Model YD-200 Incinerator

¡î Model YD-150 Incinerator

¡î Model YD-300 Incinerator

¡î Model YD-500 Incinerator

¡î Model YD-600 IncineratorNew

 Large MSW Incinerator

¡î Model MSW1000 Incinerator

¡î Model MSW2000 Incinerator

¡î Model MSW3000 IncineratorNew

¡î Model MSW4000 Incinerator

¡î Model MSW5500 Incinerator

 Small Incinerator

¡î Model YD-10 Incinerator

¡î Model YD-15C Incinerator

¡î Model YD-20C Incinerator

¡î Model YD-30C Incinerator

¡î Model YD-50C Incinerator

 Pet Crematory

¡îAnimal Crematory A360

¡îAnimal Crematory A600

¡îAnimal Crematory A900New

¡îAnimal Crematory A1500

¡îAnimal Crematory A2400

¡îAnimal Crematory A4000

¡î Model SYC-50 Incinerator

¡î Model SYC-100 Incinerator

 Economical Incinerator

¡î Model YZ-20 Incinerator

¡î Model YZ-50 Incinerator

¡î Model YZ-100 Incinerator

¡î Model YZ-150 Incinerator


>Light Oil Burner

>Gas Burner

>Incinerator FAQ (PDF)

>How to Buy

>Photo Gallery 

>Certificate

Request Dealer

> Tiếng Việt

> SiteMap

>Incinerator News

>Incinerator Questions

>Incinerator Inquire in History

>Market Analytics

>Friendly Links

¡¡

¡¡

Incinerator Question

Call us on  0086-25-8461 0201  Email: [email protected]

¡¡

Date: 2013-06-06

  Incinerator Question:  

  Tag:  Saudi Arabian, Medical Incinerator Plant, Incinerator YD-50

Technical specification for burning machine
1. Two systems are required to be installed in the south of the Kingdom of Saudi Arabia. The two systems will be used by custom authority to burn different kinds of drugs. All need equipment must be provided.
2. Warrantee: booth systems must be provided with 3 years warrantee from the date of acceptance. All needed spare parts, preventative maintenance repair and corrective maintenance must be included in the cost and provided to the customer.
3. All needed electric and water connections must be provided.
4. Both systems must be of high quality and must be environmental friendly.
5. The capacity of each system should be up to 100 kg/hr.
6. The system must have automatic feeding.
7. Each system must consists of two burning rooms, one primary room for burning the drug and another room for burning the gases that emit as a result of primary burning.
8. The oven must be made of steel that is rust resistance and with thickness not less than 6 mm.
9. Each system must be of high efficient in burning different kinds of drugs, and should have 99.9% efficiency for burning organic materials.
10. Waste products should not exceed 5%.
11. System must have automatic ignition system.
12. System should use diesel (HSD) as fuel and should not consume more than 8 to 10 lt/hr .
13. Each system should be provided with fuel tank of size adequate to operate the system for one full day.
14. The temperature in the primary room should be 850 C ¡À 50 C. the system should also be capable to operate up to 1050 C ¡À 50 C. the system should be capable of continues operation and should be provided with cement layer insulator with adequate thickness.
15. Oven should be provided with heat insulator to allow easy operation.
16. Gas should remain in the secondary room for not more than 1.5 second.
17. The primary burning room should have at least 2 burners.
18. The secondary burning room should have one burner.
19. Each system should have doors for ash, exit for air to the chimney and windows to allow looking inside and for maintenance.
20. Each system should have filtering system for gas processing with 2 tanks using ordinary water. Each water tank should have capacity of 1000 lt and should be fixed to the system and provided with water level indicator.
21. Each system should have special technology for separating waist products and humidity after gas processing.
22. Each system should have cooling capability after operation.
23. Each system m should be provided with exhaust pipe with 250 mm diameter and 10 m high. The base of the exhaust system should be 1000 mm. The exhaust pipe should be 6 mm and should be provide with heat insulator. The exhaust system should be provided with pressure indicator. It should also provide with ladder and Lightning Arrestor.
24. Electric power: should be 220 volt, 3 phase, 60 Hz, and the motor should not be less than 15 HP.
25. Each system should be provided with control panel and indicators and needed safety equipment and alarm systems. The control panel should show at least temperature in both the primary and secondary rooms and injectors of the filters and load.
26. Each system should be provided with alarm system for any breakdown or defect of any component of the system.
27. The following personal protective tools must be provide:
a. Heat resistant garments for 20 persons.
b. Heat resistant goggles for 20 persons.
28. All components of each system should be painted with silver color that is heat resistant.
¡¡

  Incinerator Answer:  

  reference website: http://www.clover-incinerator.com/incineratoryd50.htm

pet incinerator price incinerator china medical incinerator small scale incinerator clover incinerator incinerator 500kg per medical
waste incinerator


animal incinerator prices china incinerator incinerator animal incinerator price clover incinerater incinerator installation demo
incinerator manufacturers china small incinerator

¡¡

¡¡

¡¡

¡¡

¡¡

¡¡

¡¡

¡¡

¡¡

November, 2012

2012-11-18

2012-11-19

2012-11-20

2012-11-21

2012-11-22

2012-11-23

2012-11-24

2012-11-25

2012-11-26

2012-11-27

2012-11-28

2012-11-29

2012-11-30

December, 2012

2012-12-01

2012-12-02

2012-12-03

2012-12-04

2012-12-05

2012-12-06

2012-12-07

2012-12-08

2012-12-09

2012-12-10

2012-12-11

2012-12-12

2012-12-13

2012-12-14

2012-12-15

2012-12-16

2012-12-17

2012-12-18

Jun, 2013

2013-06-01

2013-06-02

2013-06-03

2013-06-04

2013-06-05

2013-06-06

2013-06-07

2013-06-08

2013-06-09

2013-06-10

2013-06-11

2013-06-12

2013-06-13

2013-06-14

2013-06-15

2013-06-16

2013-06-17

2013-06-18

2013-06-19

2013-06-20

2013-06-21

2013-06-22

2013-06-23

2013-06-24

2013-06-25

2013-6-26

2013-06-27

2013-06-28

2013-06-29

2013-06-30

¡¡

Nanjing Clover Medical Technology Co., Ltd.

Rm.411, 07 Building, East Wanda Plaza, 58# Yunjin Road, Nanjing, P.R.China Post Code: 210019
Tel: +86-25-84610201 Fax: +86-25-84610406
Website: www.clover-incinerator.com Email: [email protected]

Copyright 2010 Clover Medical Limited All Rights Resered.