CLOVER Incinerators
Medical Incinerator, Animal Cremation, Waste Incinerator
Home YZ Incinerator YD Incinerator SYC Incinerator CONVO Incinerator Containerized Incinerators

Burners

Contact Us

 
Light Oil Burner Heavy oil Burners Gas Burner Dual Fuel Burner
Light Oil/Gas
Burner Fittings

Burner Performance feature
Al-in-one blower.
Auto-operation
Manual switch for one stage/two stage
Gas auto-leakage(option)double solenoid valve (single vafive for one stage)
Protect for the gas pressure ensure to stop burner running when the gas pressure is too high or too low.
Protect for the air pressure ensure to stop burner running when the air pressure is too low.
Sweep the tube before ignition.
Safety flame monitors system.
The servo motor will close the air gate when stop the burner.(manual adjust the air gate for one stage)
The servo motor moves the camto control the air gate and the gas butterfly valve which adjusting the consumption of air and gas.(For modulating & Sliding series)
Convenient for the installation,commissioning and maintenance because the gemel connection between the burners body and tube
The burner is easy to install for the portable body,The client just connects the power supply and gas suply and gas supply then can start the burner.
The little running noise and the discharge gas can suitable for the demands of the environmental protection.
Can suitable different kind of fuel gas.
The standard collocate Electric protect grade is IP40.

Burner Operation

BT...GF On-off
BT...GRF HI-LOW with servo motor
BT...GS/M Sliding/Modulting with servo motor

Gas Burner - One-Stage Gas Burner - Modulating Gas Burner
 Model Output max.(Kw) Output min.(Kw)  Model Output max.(Kw) Output min.(Kw)
 BT3GF 41.9 16.3  BT17GS/M 168 50
 BT6GF 56.3 30.6  BT35GS/M 340 60
 BT11GF 99 48.8  BT40GS/M 425 185
 BT17GF 168 69  BT60GS/M 738 248
 BT20GF 200 50  BT100GS/M 995 280
 BT30GF 300 60  BT120GS/M 1200 350
 BT35GF 358 90  BT150GS/M 1428 414
 BT50GF 596 169  BT200GS/M 2000 490
 BT60GF 738 248  BT250GS/M 2500 590
Gas Burner - TWO-Stage  BT350GS/M 3500 924
 Model Output max.(Kw) Output min.(Kw)  BT400GS/M 3800 924
 BT17GRF 168 69  BT450GS/M 4000 550
 BT20GRF 200 50  BT550G S/M 5400 600
 BT30GRF 300 60  BT650G S/M 7400 800
 BT35GRF 358 90  BT1000G S/M 10500 1000
 BT40GRF 425 185 Gas Burner - Coal-gas-burner
 BT60GRF 738 248  Model Output max.(Kw) Output min.(Kw)
 BT100GRF 995 280  BT11TGF 109 48
 BT120GRF 1200 350  BT17TGF 150 69
 BT150GRF 1428 414  BT30TGF 208.8 101
 BT200GRF 2000 490  BT40TGF 320 186
 BT250GRF 2500 590  BT60TGF 465 184
 BT300GRF 2982 657  BT30TGF 208.8 101
 BT350GRF 3500 924  BT35TGF 279 128
 BT400GRF 3950 924  BT40TGF 320 186
Model Specification  BT60TGF 465 184
TC-10G OFF-ON, Output(10Kcal/H):1-2  BT100TGF 755 355
TC-30G OFF-ON, Output(10Kcal/H):3  BT150TGF 1451 653
GOM-2 OFF-ON, Output(10Kcal/H):12  BT250TGF 2362 715
GOM-3 OFF-ON, Output(10Kcal/H):20      
AG-100 Two stage, Output(10Kcal/H):80      

*Home * YZ Incinerator * YD Incinerator * SYC Incinerator * CONVO Incinerator * Containerized Incinerator * Burner * Contact Us
*
10kgs per hour Incinerator * 20kgs per hour Incinerator * 30kgs per hour Incinerator * 50kgs per hour Incinerator *
*
100kgs per hour Incinerators * 150kgs per hour Incinerator * 300kgs per hour Incinerator * 500kgs per hour Incinerator *
 

Nanjing Clover Medical Technology Co., Ltd.

Rm.411, 07 Building, East Wanda Plaza, 58# Yunjin Road, Nanjing, P.R.China Post Code: 210019
Tel: +86-25-84610201 Fax: +86-25-84610406
Website: www.clover-incinerator.com Email: [email protected]

Copyright 2010 Clover Medical Limited All Rights Resered.